Share on (1600887669990):
NO. | Item | Specifications | ||||
1 | Minimum capacity | *20.0Ah | 0.5C@3.65~2.5V@25±2℃ | |||
2 | ACIR@1KHz | ≤1.5mΩ | 27%SOC@25±2℃ | |||
3 | Weight | About 423g (±5%) | ||||
4 | Charge cut-off voltage | 3.65V | ||||
5 | Discharge cut-off voltage | 2.50V | ||||
6 | Operating voltage rang | 2.50~3.65V | ||||
7 | Nominal voltage | 3.2V | 0.5C@3.65~2.50V@25±2℃ | |||
8 | Operating temperature | Charge | 0~15℃ | 0.2C to 3.50V | ||
16~35℃ | 0.5C to 3.65V | |||||
36~55℃ | 0.5C to 3.65V | |||||
Discharge | -20~60℃ | |||||
9 | Standard charge method | 0.5C CC to 3.65V,3.65V CV to 0.05C | ||||
10 | Standard discharge method | 0.5C | ||||
11 | Max continuous charge current | 2.0C | ||||
12 | Max continuous discharge current | 5.0C | ||||
13 | Storage temperature (27%SOC state) | 12month | -20~25℃@80%RH max | |||
3month | -20~35℃@80%RH max | |||||
1month | -20~45℃@80%RH max |
Grouping standard | ||||||||
Cell assembly standard | Capacity | Voltage | Internal resistance | k value | ||||
*300mAh | *5mV | 0.4mΩ | ≤0.03mV/h |
Item | Test method | Standard | |
1 | Appearance | Visual | No Defects and Leakage |
2 | Dimension | Caliper for dimension | As item 4 |
3 | Weight | Balance | As item 3.3 |
4 | Shipment voltage | Voltmeter | 3.20~3.30V(27±3%SOC) |
5 | Initial Internal Impedance | Measure the AC impedance at 1kHz | ≤1.5mΩ (27% SOC) |
7 | Cycle Life (25±2℃, With splint ,Rest for 30 min between each cycle.) | Charge: 1.0C CC charge to 3.65V, 3.65V CV charge to 0.05C cut-off; Discharge: 1.0C CC discharge to 2.5V | ≥80%Initial capacity @2000 cycles |
9 | Leakage Test | The battery which is fully charged shall be stored at 60±2℃ and 85±5% RH for 7 days. | No Leakage. |
10 | H/L Temp. Characteristic (Hold for 5h@55℃ or 20h@-20℃ after full charging) | Charge: 0.2C CC charge to 3.65V, 3.65V CV charge to 0.05C cut-off at 25±2℃ Discharge: 0.3C CC discharge to 2.0V at -20±2℃ ; 1.0C CC discharge to 2.5V at 55±2℃. | Discharge capacity rate: *≥50%Initial Capacity -20±2℃ *≥90%Initial Capacity 55±2℃. |
Item | State | Test method | Standard |
External Short | Fully Charged | Battery terminals are short-circuited with a resistance of less than 5mΩ for 10minutes. Observe 1 hour. Tests are to be conducted at room temperature. | NO EXPLOSION AND NO FIRE. |
Over-Discharge | Fully Discharged | 1C CC discharge for 90minutes after standard charge,Observe 1 hour. | NO EXPLOSION NO FIRE AND |
Heating | Fully Charged | Put the battery into an oven at RT, and increase the temperature at a rating of 5℃/min to 130±2℃, after the oven temperature reached to 130℃±2℃, maintain for 30 minutes at that temperature before the test is discontinued.,Observe 1 hour. | NO EXPLOSION AND NO FIRE. |
Crush | Fully Charged | Crush battery with half cylinder at a speed of not faster than 2mm/s. The radius of the half cylinder is 75mm. Stop to crush when voltage reached 0V or deformation amount reached 15% or pressure reached 100kN, Observe 1 hour. | NO EXPLOSION AND NO FIRE. |
Overcharge Test | Fully Charged | 0.5C CC Charge the battery to 1.1times of the max charge voltage or continue to charge for 1hour after charge the battery to the 115%soc, Observe 1 hour. | NO EXPLOSION AND NO FIRE. |
Temperature Cycling Test | Fully Charged | Reducing the chamber temperature to -40℃ within 60 minutes and maintaining this temperature for 90 minutes, Raising the chamber temperature to 25 ℃ within 60minutes, Raising the chamber temperature to 85℃ within 90minutes and maintaining this temperature for 110 minutes, Reducing the chamber temperature to 25℃ within 70minutes.Repeating the sequence for a further 4cycles, Observe 1 hour | NO EXPLOSION NO FIRE AND |