Comprehensive name | Welbee Inverter A350P | |||||||||
Welding power supply | WB-A350P | |||||||||
Welding torch | AWD-17(Air Cooling) | AWD-26(Air Cooling) | AWD-18(Water cooled) | |||||||
Torch joint | / | |||||||||
Base metal cable | BKPDT-3803 | |||||||||
trachea | BKGFF-0603 | |||||||||
Water pipe | / | / | BBDW-3001/3002 | |||||||
Argon flow regulator | HLAR19-25L | |||||||||
Standard style | ||||||||||
Comprehensive name | Welbee Inverter A350P | |||||||||
Welding power supply | form | WB-A350P | ||||||||
Rated output current | A | Ac TIG | Dc TIG | Ac MMA | Dc MMA | |||||
350 | 350 | 250 | 250 | |||||||
Rated input voltage | V | 380V | ||||||||
Phase number | / | Three phase | ||||||||
Rated frequency | Hz | 50/60 | ||||||||
Rated power | kVA | 12.2(10.2kW) | 12.3(10.8kW) | 15.6(10.2kW) | 10.5(9.1kW) | |||||
Maximum no-load voltage | V | 70/77 | ||||||||
Rated utilization rate | % | 40 | ||||||||
Rated load voltage | V | 24 | 24 | 30 | 30 | |||||
Output current range | A | 5~350 | 2~350 | 10~250 | 10~250 | |||||
5~250(Soft arc mode) | ||||||||||
Advance the pumping time | seconds | 0~99 | / | |||||||
Delayed pumping time | seconds | 0~99 | / | |||||||
Slow rise time | seconds | 0~10 | / | |||||||
Downshift time | seconds | 0~10 | / | |||||||
Pulse frequency | Hz | 0.1~999 | / | |||||||
Pulse width | % | 50 | / | |||||||
Ac frequency | Hz | 30~500 | / | 50/60 | / | |||||
Clearing width adjustment | % | -20~20 | / | |||||||
AC-DC switching frequency | Hz | 0.1~50 | / | |||||||
Automatic arcing control | Yes/No/Repeated | / | ||||||||
Spot welding time | seconds | 0.1~10 | / | |||||||
Welding condition memory | 100 | |||||||||
Class of protection | IP23 | / | ||||||||
Overall dimension | mm | 395x710x640(without ring) | ||||||||
weight | 56 | |||||||||
Arcing mode | High frequency /contact arcing | / | ||||||||
※ If the AC frequency is higher, the actual welding current may be higher than the set current. | ||||||||||
Welding torch | form | AWD-17 | AWD-26 | AWD-18 | ||||||
Rated current | A | 150(DC)、130(AC) | 200(DC)、160(AC) | 350(DC)、270(AC) | ||||||
Utilization rate | % | 50 | 50 | 100 | ||||||
Cooling mode | Air cooling | Air cooling | water-cooling | |||||||
Electrode diameter in use | mm | (0.5)、(1.0)、(1.6)、(2.0)、(2.4) | (0.5)、(1.0)、(1.6)、(2.0)、(2.4)、(3.2)、(4.0) | (0.5)、(1.0)、(1.6)、(2.0)、(2.4)、(3.2)、(4.0) | ||||||
Cable length | m | 48 | ||||||||
※ () Internal electrode optional | ||||||||||
Argon gas flow regulator | form | HLAR19-25L | ||||||||
Maximum discharge | / min | 25 |