Share on (1600962004459):
Parameters | ||||||||
Continuous output power | 350W@35℃@ Rated input voltage | 500W@35℃@ Rated input voltage | ||||||
Surge power | 700W@5S | 1000W@5S | ||||||
Surge current when power on | < 30A | < 50A | ||||||
Output voltage | 220VAC (±3%); 230VAC (-6%~+3%); 240VAC (-9%~+3%) | |||||||
Output frequency | 50/60Hz ± 0.2% | |||||||
Output wave | Pure Sine Wave | |||||||
Output distortion THD | THD ≤ 3% (Resistive load) | |||||||
Load power factor | 0.2 ~ 1 (Load power ≤ Continuous output power) | |||||||
Rated input voltage | 12VDC | 24VDC | 12VDC | 24VDC | ||||
Input voltage range | 10.8 ~ 16.0VDC | 21.6 ~ 32VDC | 10.8 ~ 16.0VDC | 21.6 ~ 32VDC | ||||
Rated output efficiency① | > 89.0% | > 90.0% | > 89.5% | > 91.5% | ||||
Max. output efficiency | > 90.0% (70% loads) | > 91.5% (70% loads) | > 91.0% (40% loads) | > 92.0% (40% loads) | ||||
Idle current | < 0.15A | < 0.10A | < 0.15A | < 0.10A | ||||
No-load current | < 0.9A | < 0.4A | < 0.9A | < 0.6A | ||||
USB output | 5VDC/Max.1A | |||||||
RS485 com. port | 5VDC/200mA | |||||||
Mechanical parameters | ||||||||
Input terminal | M6 | M6 | ||||||
Dimension (L x W x H) | 229 × 163.5 × 75mm (with decorative cover) 229 × 160 × 73mm (without decorative cover) | 286 × 163.5 × 78mm (with decorative cover) 286 × 160 × 78mm (without decorative cover) | ||||||
Mounting size (L x W) | 205 × 75mm | 262 × 75mm | ||||||
Mounting hole size | Φ5mm | Φ5mm | ||||||
Net Weight | 1.5kg | 2.3kg | ||||||
Environment parameters | ||||||||
Environment temperature | -20℃ ~ +60℃ (Refer to the Derating Curve) | |||||||
Storage temperature | -35℃ ~ +70℃ | |||||||
Relative humidity | < 95% (N.C.) | |||||||
Enclosure | IP20 | |||||||
Altitude | < 5000m (If the altitude exceeds 1000 meters, the rated power will be reduced according to IEC62040.) | |||||||
Certification | ||||||||
Safety | EN/IEC62109-1,UL1741,UL458,CSA C22.2#107.1 | |||||||
EMC (Electromagnetic compatibility) | EN61000-6-1/EN61000-6-3 FCC 47 CFR Part 15,Subpart B | |||||||
RoHS | IEC62321-3-1 | |||||||
① It is measured in the condition of continuous output power and rated input voltage. | ||||||||
② It means the max. output efficiency when the inverter is connected with different loads under the rated input voltage. | ||||||||




New products from manufacturers at wholesale prices