Share on (1600998717116):
MODEL | ALPHA ESS 1KVA/1.28KWH | ALPHA ESS 3KVA/2.56KWH | ||
SPECIFICATION | ||||
Inverter / Charger | ||||
Inverter Type | 1KVA/12V | 3KVA/24V | ||
Rated Output Power | 1KW | 2.7KW | ||
Output Voltage Waveform | Pure Sine Wave | Pure Sine Wave | ||
Output Voltage | 230VAC 50HZ | 230VAC 50HZ | ||
Charging Current(Utility and solar together) | 60A Max. | 80A Max. | ||
AC Input | ||||
Nominal Input Voltage | 230Vac | 230Vac | ||
Voltage Range | 170-280Vac(UPS), 90-280Vac (Appliances) | 170-280Vac(UPS), 90-280Vac (Appliances) | ||
Nominal Input Frequency | 50HZ / 60HZ(Auto detection) | 50HZ / 60HZ(Auto detection) | ||
AC Charging Current | 20A Max. | 60A Max. | ||
Solar Input | ||||
Nominal PV Voltage | 36Vdc | 240Vdc | ||
PV Array MPPT Voltage Range | 15Vdc~80Vdc | 30Vdc~350Vdc | ||
Max. PV Array Open Circuit Voltage | 115Vdc | 400Vdc | ||
Solar Charging Current | 40A Max. | 80A Max. | ||
Lithium Iron Battery | ||||
Capacity | 1280Wh | 2560Wh | ||
Nominal Battery Voltage | 12.8Vdc | 25.6Vdc | ||
Typical Capacity | 100Ah | 100Ah | ||
Max.Charge Current | 50A | 50A | ||
Max.Discharge Current | 100A | 100A | ||
Operation Voltage Range | 11.2Vdc~14.6Vdc | 22.4Vdc~29.2Vdc | ||
Operation Temperature | -10℃~+50℃ | |||
Protection | ||||
Protection | Overcharge/Overdischarge/Overcurrent/ Overtemperature/Shortcircuit protection | |||
Ambient | ||||
Noise(dB) | < 40dB (1 meter) | |||
working Temperature | -10℃~+50℃ | |||
Humidity | 0~95% ( no condensation) | |||
Sea Level(m) | ≤1500 | |||
Dimension | ||||
L×W×H (products size) | L450*W213*H636mm | L450*W279*H731mm | ||
















New products from manufacturers at wholesale prices