adjustable 60 programs EMS Interferential Russian waveform Physiotherapy Tense Unit

Share on (1601012563891):


Price:$10.04 - $19.25

Quantity:


Product Overview

Description



Product Overview


Professional TENS/EMS/IF/RUSS Device
IF is Interferential Current. RUSS is Russian Stimulation.
Product Advantages:
1. A total of 60 programs(Mode).
2. TENS: 23 fixed + 2 adjustable programs.
3. EMS: 13 fixed + 2 adjustable programs.
4. IF: 8 fixed + 2 adjustable programs.
5. RUSS: 8 fixed + 2 adjustable programs.
6. Adjustable intensity:0 - 120 levels. Max: 120mA.
7. Adjustable working time:5 - 90 minutes. 1min/step.
8. Mode and intensity of two-channel can be controlled separately.
9. The frequency and pulse width of each program displayed on the display screen, and customers can clearly know the parameters of each program.




Customized Programs
TENS : Adjustable Frequency: 1 Hz - 800 Hz, 1 Hz/step. and Adjustable Pulse width : 50 us - 300 us, 1 us/step.

EMS : 1. Adjustable Frequency: 1 Hz - 800 Hz, 1 Hz/step. 2. Adjustable Pulse width : 50 us - 300 us, 1 us/step.
3. Ramp Up time : Adjustable, from 1 to 9 sec. 4. Contraction Time: Adjustable, from 1 to 60 sec. 5. Ramp Down Time: Adjustable, from 1 to 9 sec. 6. Relaxation (OFF)time : Adjustable, from 1 to 60 sec.

IF (Interferential Current)
1. PU1 Mode: Channel 1 – Fundamental frequency: 4000 Hz fixed, Channel 2 – Selectable frequency: 4001 to 4150 Hz Interference frequency: 1 to 150 Hz.
2. PU2 Mode:Channel 1 – Fundamental frequency: 2500 Hz fixed, Channel 2 – Selectable frequency: 2501 to 2650 Hz Interference frequency: 1 to 150 Hz.

3. Adjustable Cycle time: from 5 to 60 sec.

RUSS (Russian Stimulation)
1. PU1 Mode: Carrier Frequency (Fixed):2500Hz; frequency: Adjustable, from 1Hz to 100Hz, 1 Hz/step.
2. PU2 Mode: Carrier Frequency (Fixed): 2000Hz; frequency: Adjustable, from 1Hz to 100Hz, 1 Hz/step.

2. Adjustable Cycle time: from 5 to 60 sec.








Function


IF(Interferential Current) Function;
Promote tissue healing, improve circulation to injured tissues, pain relief, relieve muscle spasm, edema reduction, stimulate deeply situated muscles such as the pelvic floor muscles. chronic intractable pain and post-surgical and post-trauma acute pain relief.

RUSS(Russian Stimulation) Function;
Strengthening muscles, increasing muscle size, improving muscular endurance, accelerating muscle recovery and reduce muscle spasms. Especially for athletes: such as anterior cruciate ligament (ACL) tears, with physical therapy programs to improve strength.

TENS Function
1. Relieve arthritis pain and nerve pain.
2. Rehabilitation and treatment of post-operative pain.
3. Relieve joint pain, chronic intractable pain.
4. Relieve pain for back, knees, shoulder, ankles, wrists, elbows, etc.

EMS Function
Suitable for sportspeople: Pre-training warming up and Post-training recovery (Endurance/Maximum strength/Explosive Strength/Toning).
1. Retarding or preventing muscle atrophy.
2. Relax muscle spasm and reduce muscle soreness.
3. Increase muscle growth and increase local blood circulation.


PRODUCT SPECIFICATIONS


Product Name
Medical TENS/EMS/IF/RUSS Device
Intensity
0 - 120 levels. Max: 120mA.
Programs
Total  60 Programs


TENS and EMS belong to low frequency. The frequency is generally between 1-300Hz.

IF and RUSS are Medium-high frequency. The frequency is generally between 2000-5000 Hz.

This is a professional rehabilitation physiotherapy device.




PRODUCT CONFIGURATION


Product Features:
$ 4-in-1 Therapy Modes Featuring TENS, EMS, IF and Russian Stimulation.
$ High tech design with extra-large LCD display – Easy to see & use!
$ Preset body programs or user defined modes option.
$ Portable design for on-the-go patients with removable belt clip
$ 1 Year Manufacturer Warranty.




Whats is Interferential current
Interferential current applies two different frequencies that interfere with one another to produce a medium frequency current within the tissues.

Interferential Current is a high frequency (4000 Hz), The TENS which typically delivers at 125 Hz. When current is applied to skin, skin resistance decreases as pulse frequency increases. Thus, Interferential Current crosses the skin with greater ease and with less stimulation than with TENS. Interferential current reaches greater depths and over a larger volume of tissue than other forms of electrotherapy.

What is Russian Stimulation

Russian Stimulation is a specific form of electrical stimulation with a symmetrical Biphasic Square waveform. It was originally developed by the Russian Olympic team intended for building muscle mass on their athletes. Russian stimulation is now more often used to re-build atrophied muscle mass and reduce edema of injured soft tissue. \u2028Russian Stimulation is designed to stimulate motor nerves at a frequency of 2500Hz allowing for deeper muscle penetration and a more complete/stronger contraction of the muscle fibers. This form of stimulation relieves muscle spasms and is beneficial for elderly patients and those suffering from scoliosis.

WARNING:
1) DO NOT apply over areas of known Cancer because of the risk to potentially spread the cancer cell through enhanced blood blow
2) DO NOT apply to patients with known Heart Disease, heart failure, or arrhythmias as it may adversely affect these disease state conditions
3) DO NOT apply over or close to areas if you have AFib or where an electronic device is implanted (pacemaker, neurostimulator bone growth stimulator, defibrillator, etc)
4) DO NOT apply over the abdomen, pelvic area, or lower back during Pregnancy
5) DO NOT use the Tens on your eyes/mouth/face, neck sides or any area of the throat
6) DO NOT use the Tens Units over Open wounds or rashes, or over swollen, red, infected, or inflamed areas
7) Please gradually increase the Intensity from low to high, do not directly drive to the highest level
8) For those symptoms not illustrated apply the electrodes around the source of the pain or seek advice from your medical advisor



SALES AND SERVICE NETWORK


Our Services & Strength
Printing of your company's LOGO on the machine. / All information displayed on the product is in English / Shipment of products directly from the factory, in secure packaging. / All products are new (unused) in packages adapted for retail customers. / Fast shipping with Express delivery within 1-2 days. / Transaction security, Alibaba Trade Assurance service. / Transport products economically, saving money on shipping costs. / Reduce the value of goods declared to reduce duties. / If there is any quality problem, we will replace it with a new product. / Sending promotional material necessary for product marketing.




SIMILAR PRODUCTS




Successful Project


"JRW" Manufacturer was founded in 2006 in China Shenzhen and specialized in Healthcare products. We have passed the factory audit from the third party. Almost 90% of products have mold, so it's easy to control the cost! Nearly 8000 square meters of factory area, more than 800 employees; We have our own R&D center and an integrated one-stop production chain.




FAQ


1. Q: What's MOQ for this item?
A: Minimum Order Quantity: 1 pcs.

2. Q: How many days can I get the goods after payment?
A: Usually, we will ship the goods within 2 days. if by Express, it takes 3-5 days.

3. Q: What's the package for this item?
A: the package is carrying case, The price on Alibaba does not include accessories. Please consult our salesperson for specific prices.

4. Q: Are you able to customize items with a design or logo?
A: Yes, Welcome OEM order , including printing your LOGO and customize the gift box or suitcase.

6. Q: How could you ensure excellent quality?
A: All of our items are from the factory directly, Any quality problem, we will replace a new one for free.

7. Why pads no sticky after several days?
A: Skin must be clean and dry. Dirty or oily skin will prevent electrode adhesion. Applying a few drops of water after usage will increase the longevity of the pads and let them dry naturally . Place pads on the holder or place plastic film to keep the gel moisture after use.


0.199 s.