Share on (1601022036198):
Model | GreenLine 1.20 Ti | GreenLine 1.26Ti | GreenLine 1.30 Ti | GreenLine 1.35 Ti | ||||
Combustion chamber type | Closed: removal of combustion products due to forced draft created by the fan | |||||||
Type of gas | Mechanical | |||||||
Nominal pressure of natural gas(mbar) | 20 | 50 | 80 | 100 | ||||
Connecting pressure of natural gas(mbar) | 5-25 | |||||||
Burner heat output range (min.-max.)(kW) | 7.5-20.0 | 9.8-26.0 | 12.5-30.0 | 8.0-35.0 | ||||
Heat output range in heating mode(min.-max.)(kW) | 7.0-19.2 | 9.1-24.6 | 11.8-28.5 | 7.6-34.6 | ||||
Thermal power range in DHW mode (min.-max.)(kW) | 7.7-20.4 | 10.0-26.5 | 12.7-30.3 | 8.4-36.5 | ||||
Max natural gas consumption(m³/h) | 2.1 | 2.75 | 3.18 | 3.7 | ||||
Efficiency of rated heat load at 80℃/60℃ for water supply and return(%) | 96 | |||||||
Efficiency of rated heat load at 50℃/30℃ for water supply and return(%) | 102 | 102 | 102 | 100 | ||||
Partial heat load efficiency(%) | 105 | |||||||
Heating system | ||||||||
Temperature control range(℃) | 35-85 | |||||||
Maximum cooling temperature(℃) | 90 | |||||||
Maximum cooling temperature(bar) | 3 | |||||||
Expansion tank volume(L) | 6 | 6 | 6 | 10 | ||||
Expansion tank volume | ||||||||
Operating voltage / frequency(V/Hz) | 230±10%/50 | |||||||
Power consumption(W) | 105 | 115 | 120 | 125 | ||||
Overall and connecting dimensions | ||||||||
Height(mm) | 725 | 725 | 725 | 760 | ||||
Width(mm) | 400 | 400 | 400 | 488 | ||||
Width(mm) | 325 | 325 | 325 | 330 | ||||
Net weight(kg) | 35 | 36 | 37 | 45 | ||||
Heating supply(inch) | 3/4 | |||||||
Heating return(inch) | 3/4 | |||||||
Cold water inlet(inch) | 1/2 | |||||||
Hot water outlet(inch) | 3/4 | |||||||
Gas connection(inch) | 3/4 | |||||||
Smoke/air duct system | 60/100 |