M driver Single Phase to 3 Phase Frequency Converter 50hz 60hz 2.2kw 220v VFD Drives

Share on (1601047744014):


Price:$45.00 - $62.00

Quantity:


Product Overview

Description



900 series VFD


solarapp.jpgProduct Description


 


M-driver Single Phase to 3 Phase Frequency Converter 50hz 60hz 2.2kw 220v VFD Drives 





































ModelM900-0022G1
Rated Voltage220v/230/240vac/150vdc-400vdc
Output Frequency Range0-500hz
Control ModeV/F Control,Vector,PID,torque control
Communication portRS485 modbus
VibrationLess than 5.9m/s
IP LevelIP20
Protection functionshort circuit,phase loss,overcurrent,over voltage,under voltage,overheating,overload,etc

 


 


 








































































































ItemSpecifications
Basic functionOver load capabilityG type:150% rated current 60s;180% rated current 3s
P type:120% rated current 60s;150% rated current 3s
Torque boostAuto torque boost function; Manual torque boost 0.1%~30.0%
V/F curveLinear V/F, multi-point V/F and square V/F curve(power of 1.2,1.4,1.6,1.8,2)
V/F separation2 ways: separation and semi-separation
Acc./dec curveStraight line or S curve acceleration and deceleration mode,time range between 0.0 to 500.0s
DC brakingDC braking frequency:0.00Hz to maximum frequency. Braking time:0.0s to 36.0s
Brake current value:0%-100%
Jog controlJog frequency range:0.00Hz~50.00Hz; 
Jog acceleration/deceleration:0.0s~6500.0s.
Basic function Multiple segment speed runningIt can realize at maximum of 4 segments speed running via the control terminal.
Built-in PIDIt is easy to realize process-controlled closed loop control system.
Over-voltage/current stall controlIt can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping during the running process.
Personalized functionInstantaneous stop non-stopWhen instantaneous power off, voltage reduction is compensated through load feedback energy, which could make AC Drive keep running in a short period of time.
Rapid current limitTo avoid AC Drive frequent over-current fault.
Timing controlTiming control function:set time range 0Min~6500.0Min.
RunningCommand sourceOperation panel reference, control terminal reference and serial communication port reference. 
Frequency source Digital reference, analog signal reference , Multi-Segment speed reference, PID and communication reference.
Input terminal5 digital input terminals.
2 analog input terminals.
1 supporting 0-10V voltage input or 0~20mA current input terminal.
Output terminal 2 relay output terminals.
1 analog output terminals, supporting 0~10V voltage output or 0~20mA current output.
EnvironmentAmbient Temperature-10 ℃ to +40 ℃ (Derating use when under ambient temperature of 40 ℃ to 50 ℃)

 


 


 


 


1phdia.jpgvsd.jpgsensorcon.jpgMore products,please click the below pictures


 






























1.jpg2.jpg3.jpg
4.jpg5.jpg6.jpg
7.jpg8.jpg9.jpg
10.jpg11.jpg12.jpg
13.jpg14.jpg15.jpg

4pro


applicationfactoryexhibition 750certificate.jpg 




0.0912 s.