Share on (1601061452385):
LC3200 Original Factory High Pressure Liquid Chromatography HPLC Chromatography Machine Price
Introduction of High Performance Liquid Chromatography
High performance liquid chromatography (HPLC) is an important qualitative and quantitative technique, generally used for the estimation of pharmaceutical and biological samples. It is the most versatile, safest, dependable and fastest chromatographic technique for the quality control of drug components.
Parameters of High Performance Liquid Chromatography
| LC3200 Original Factory High Pressure Liquid Chromatography HPLC Chromatography Machine Price | |
| System | |
| Qualitative repeatability | RSD≤0.2% |
| Quantitative repeatability(Area) | RSD≤0.4% |
| Pump | |
| Flow Rate Range | 0.001-10.000mL/min |
| Max Operating Pressure | 42MPa |
| Pressure Pulsation | <0.1MPa |
| Flow Rate Set Error | ±0.2% |
| Flow Rate Stability | RSD≤0.06% |
| Gradient Error | ±1% |
| Column Oven | |
| Temperature Range | 4 °C ~ 85 °C |
| Temperature Stability | ±0.2°C |
| Temperature Precision | ±0.1 °C |
| Autosampler | |
| Injection Volume Repeatability | <0.5%RSD |
| Linearity | >0.999 |
| Cross Contamination | <0.002% |
| Injection Accuracy | ±1% |
| Sample Position | 120 (2*60, 2ml) |
| Syringe | Standard: 500μl, optional: 250 μL, 1000μl, 2500μl |
| Sample Loop | Standard: 100μL, optional: 10μl, 20μl, 50μl, 200μl |
| UV Detector | |
| Baseline Noise | ≤2.0×10-6Au |
| Baseline Drift | ≤1×10-5Au/h |
| Min Detection Concentration | ≤3.0×10-9g/mL(naphthalene/methanol) |
| Spectral Range | 188-900nm |
| Wavelength Error | ≤±0.1 nm |
| Wavelength Repeatability | ≤ ± 0.1 nm |
| Linearity Range | ≥ 103 (general parameters) |
| DA Detector | |
| Baseline Noise | ≤ 4×10-5Au |
| Baseline Drift | ≤ 3×10-5 Au/h≤ 3×10-5 Au/h |
| Minimum Detection Concentration | ≤ 2×10-8 g/mL |
| Spectral Range | 190-800 nm |
| Wavelength Error | ≤ ± 0.1 nm |
| Wavelength Repeatability | ≤ ±0.1 nm |
| Linearity Range | ≥ 104 |
| ELS Detector | |
| Baseline Noise | ≤ 0.0037mV |
| Baseline Drift | ≤ 0.0026mV/30min |
| Minimum Detection Concentration | ≤ 1×10-6g/mL (national standard method, cholesterol/methanol), ≤ 1×10-9g /mL (direct injection, glucose) |
| Evaporation Gas Flow Range | (0 ~ 3) SLM |
| Atomization Temperature Range | Room temperature ~ 90℃ |
| Evaporation Temperature Range | Room temperature~110℃ |
| Detection Chamber Temperature Range | Room temperature~60℃ |
| Input Air Pressure | 4~7 bar |
| FL Detector | |
| Baseline Noise | ≤5*10-6FU |
| Baseline Drift | ≤ 2 × 10-5FU/30min |
| Minimum Detection Concentration | ≤3×10-10g/mL (naphthalene / methanol) |
| Spectral Range | (200 ~ 650) nm |
| Wavelength Error | ± 0.1 nm |
| Wavelength Repeatability | ± 0.1 nm |
| Linearity Range | ≥ 104 |
| RI Dtector | |
| Flow Cell Type | 2-chamber type |
| Measurement Method | Refractive index method |
| Refractive Index Range | 1.00 ~ 1.75 |
| Detection Range | 0.25 ~ 512 μRIU |
| Drift | 0.2 μRIU /h |
| Linearity Range | ≥ 600 μRIU |
| Noise | ≤2.5nRIU |
| Cell Volume | 8μL |
| Maximum Back Pressure | 50kPa |
Features of High Performance Liquid Chromatography
1. High pressure pump with electronic pulse suppression and solvent compression compensation, combined with a two-stage suspended power transmission mechanism to ensure high precision flow output and long service life.
2. Two optional gradient modes: binary high pressure and quaternary low pressure.
3. The column oven adopts air bath circulation mode to ensure constant temperature.
Applications of High Performance Liquid Chromatography
Pharmaceutical applications
• Tablet dissolution study of armaceutical dosages form.
• Shelf-life determinations of parmaceutical products
• Identification of active ingredients of dosage forms
• Pharmaceutical quality control
Environmental applications
• Detection of phenolic compounds in Drinking Water
• Identification of diphenhydramine in sedimented samples
• Bio-monitoring of pollutant
Forensics
• Quantification of the drug in biological samples.
• Identification of anabolic steroids in serum, urine, sweat, and hair
• Forensic analysis of textile dyes.
• Determination of cocaine and metabolites in blood
Clinical
• Quantification of ions in human urine Analysis of antibiotics in blood plasma.
• Estimation of bilirubin and bilivirdin in blood plasma in case of hepatic disorders.
• Detection of endogenous neuropeptides in extracellular fluids of brain.
FoodandFlavor
• Ensuring the quality of soft drink and drinking water.
• Analysis of beer.
• Sugar analysis in fruit juices.
• Analysis of polycyclic compounds in vegetables.
• Trace analysis of military high explosives in agricultural crops.
Case 1: Fingerprint of Gastrodia elata formula granules