Share on (1601103753155):


Model | BDM 800 | BDM 600 | BDM 400 |
Recommended Max PV Power (Wp) | 600 x 2 | 450 x 2 | 600 |
Recommended Max DC Open Circuit Voltage (Vdc) | 60 | 60 | 60 |
Max DC Input Current (Adc) | 17 x 2 | 14 x 2 | 14 |
MPPT Tracking Accuracy | >99.5% | >99.5% | >99.5% |
MPPT Tracking Range (Vdc) | 22-55 | 22-55 | 32-55 |
Isc PV (absolute maximum) (Adc) | 20 x 2 | 20 x 2 | 18 |
Maximum Inverter Backfeed Current to the Array(Adc) | 0 | 0 | 0 |
Rated AC Output Power (Wp) | 800 | 600 | 400 |
Nominal Power Grid Voltage (Vac) | 240 / 208 / 230 | 240 / 208 / 230 | 240 / 208 / 230 |
Allowable Power Grid Voltage (Vac) | 211V-264* / 183V-229* / configurable* | 211V-264* / 183V-229* / configurable* | 211V-264* / 183V-229* / configurable* |
Allowable Power Grid Frequency (Hz) | 59.3 a 60.5* / configurable* | 59.3 a 60.5* / configurable* | 59.3 a 60.5* / configurable* |
THD | <3% (at rated power) | <3% (at rated power) | <3% (at rated power) |
Power Factor (cos phi, fixed) | >0.99 (at rated power) | >0.99 (at rated power) | >0.99 (at rated power) |
Rated Output Current (Aac) | 3.33/3.85/3.48 | 2.5/2.88/2.61 | 1.67/1.92/1.74 |
Nominal Frequency (Hz) | 60 / 50 | 60 / 50 | 60 / 50 |
Maximum Output Fault Current (Aac) | 9.6A | 4.4A | 2.2A |
Maximum Number of Units Per Branch (20A)(All NEC adjustment factors have been considered) | 5/5/5 | 7/6/6 | 10/8/9 |
Weighted Averaged Efficiency (CEC) | 95.50% | 95.50% | 95.50% |