ANSI IEC CSA standard 3 phase electrical transformer price 200kva 2000 kva


Products Description


Three phase pad mounted transformer
Three phase pad mounted transformers come in two basic configurations: Radial and Loop feed, which are selected based on the type of circuit on which the transformers will be installed.The 3 phase pad mounted transformer uses aluminum or copper winding and is optimized to maximize efficiency and footprint.
Click Here To Get Quotation
Three phase pad mounted transformers are designed and manufactured to comply with ANSI, DOE, IEEE, CSA and IEC standards. With high voltages up to 34.5kV and ratings up to 10MVA. It can be single voltage or dual voltage.


Daelim Transformer Certifications
Daelim three phase pad mounted transformer has UL/cUL, CSA, CESI, IEEE certifications.In addition, Daelim's 3-phase pad mounted transformer also has SGS, CSA and other third-party inspection reports.


Local after-sales service
Complete after-sales service and installation teams in Canada, USA, Ecuador, etc.Provide 24 hours of technology and consulting services. There are local cooperation after -sales service teams with rich experience in power engineering and timely services.
Tansformer solutions
Daelim Transformer not only produces transformers, but also provides the best solution for your power project. Such as mines, factories, renewable energy power generation (wind power, solar power and BESS, etc.) to provide the best transformer solutions.


Transformer customization service
Daelim has more than 20 years of experience in exporting transformers, and the team of engineers is particularly professional and proficient in various international standards. No matter which country you are from, the team of engineers can design and produce
according to your requirements and technical parameters.
High quality and fast delivery
Daelim has a strict quality control system to ensure the high quality of each transformer. There are also UL third -party inspection agencies to conduct supervision factories every three months. Therefore, you can fully trust the transformer of Daelim.The production time of conventional power distribution transformers is 6-8 weeks


1500kVA pad mounted transformer
2500kVA pad mounted transformer
1000kVA pad mounted transformer


500kVA pad mounted transformer
3000kVA pad mounted transformer
750kVA pad mounted transformer


Pad-mounted Transformer Specifications


Pad-mounted Transformer Standard Primary
Voltage Ratings
Minimum BIL(kV)
Delta or Wye
2.4kV
45
4.16kV
60
4.8kV
60
7.2kV
75
7.62kV
95
12kV
95
12.47kV
95
13.2kV
95
13.8kV
95
16.34kV
95


Click Here For Technical Solutions


Ground Wye
Minimum BIL(kV)
4160GrdY/2400
65
12470GrdY/7200
95
13200GrdY/7620
95
13800GrdY/7970
95
22860GrdY/13200
125
23900GrdY/13800
125
24940GrdY/14400
125
34500GrdY/19920
150


Click Here To Get Transformer Price


Standard kVA Ratings
45kVA
2000kVA
75kVA
2500kVA
112.5kVA
2750kVA
150kVA
3000kVA
225kVA
3500kVA
300kVA
3750kVA
500kVA
4500kVA
750kVA
5000kVA
1000kVA
7500kVA
1250kVA
8000kVA
1500kVA
10000kVA


Pad-mounted Transformer Standard Feature


-Three-point latching door for securily
-Removable sill for easy installation
-Stainless steel cabinet hinges and mounting studs
-Bolted-on cabinet with removable sill having the folowing depths:
19" deep for 300kVA through 750 kVA
22"deep for 100okVA through 1500kVA
24" deep for 200 kVA through 3750kVA
30" deep for 5000Kva through 7500kVA
-For live front construction, externally clamped high voltage porcelain bushings with a single eyebolt clamp-type connector (accommodates #6 AWG solid to 250 MCM stranded conductors)
-For dead front construction, extemally clamped high voltage bushing wells for loadbreak or non-loadbreak inserts

-HV and LV compartment doors-hinged and lift-of type wih 120° holding bars
-Steel HV/LV compartment barrier

Click Here Get Transformer Drawings
-Padlocking facikiy with one penta-head bolt on the LV compartment door and two penta-head bolts on the HV compartment door-including 3 point aching mechanism
-HV connection: Live front-external clamoed and removable HV
bushings with eyebolt clamp type connector
-LV connection:
Extemally clamped polymer & porcelain LV bushing with 4-12 Hole spades
-Oil drain plug for 500kVA and below
-1"drain valvewith sampler for 750 kVA and above
-Oil flll plug
-Five-legged core/coilassembly
-Removable LV neutral ground strap; as required
-Nameplate per ANSI requirement
-Sel-actuating prssure relief valve
-Liting lugs(4)



Optional Accessories


-Oil level gauge
-Liquid temperature gauge
-Pressure vacuum gauge
-Welded cover with handhole
-Oil drain valve with or without sampler
-Mechanical pressure relief device mounted on tank cover
-Primary termination:
Externally clamped bushing wells with loadbreak inserts
Integral loadbreak or non-loadbreak bushings
-Secondary termination:
Externally clamped bushings with NEMA 4-hole,6-hole, 8-hole,10-hole or 12-hole spades
Spade supports are available. They are provided for 8-hole spades and larger
-Primary Switching
LBOR oil switch: one for radial feed.
Externally operated de-energized tap changer
Externally operated dual voltage switch
Externally operated A-Y switch
2-position loadbreak oil switches
4-posiion Tor V blade sectionalizing loop switches
-Over voltage Protection:
Distribution class, metal oxide arresters,3-36 kV.
Distribution class,valve-type lightning arresters,3-27 kV
-Over-current protection:
Bayonet type expulsion fuses with plastic drip cup mounted on each bayonet use
Weak link cartridge fuses
Bayonet type in series with internal partial-range current limiting fuses
Secondary under oil circuit breaker
-Additional construction options:
Stainless steel tank and cabinet design
Partial stainless steel design
30" or 34" or 40" deep cabinet
CT's or PT’s, including mounting support
LV externally mounted molded case breaker
Externally mounted kWh meter
Flip-top cabinet for low profile design
Additional externally mounted nameplate
Different paint color per requirement
-Weather cover
Transformers may feature an optional weather cover over the cabinet which is hinged to allow clearance for replacement of the bay-o-net-type fuses.
The weather cover can be lifted easily into place and secured with a single supporting arm.
The weather cover requires no additional hold down hardware
Click Here Get Transformer Quotation


Transformer Test


TEST
Daelim performs routing testing on each transformer manufactured including the following tests:
—Ratio, Polarity,and Phase Relation.
—Resistance
—Applied Potential
—Induced Potential
—Loss Test
—Leak Test
Operation tests of all devices: Al electrical and electro-mechanical devices shall be operated both in auto and manual mode for proper sequencing/staging and function.



DESIGN PERFORMANCE TEST
The design performance tests include the following:
*Temperature Rise: Our automated heat run facility ensures that any design changes meet ANSl® and IEEE® temperature rise criteria.
* Audible Sound Level: Ensures compliance with NEMAO requirements.
* Lightning Impulse: To assure superior dielectric performance, this test consists of one reduced wave,two chopped waves and one full ave in sequence,precisely simulating the harshest conditions.
* Other perfomance tests such as short-cicuit capability test,liting and moving devices test can be execuled while specified by the customer.


Company Profile


Daelim Transformer Factory
Daelim is a professional pad mounted transformer manufacturer and supplier in China.
Daelim’s pad mounted transformer types are divided into single-phase and three-phase. Daelim pad mounted transformer has CSA, UL/cUL certificate.Single phase pad mounted transformer is widely used in residential.Primary voltage up to 34.5kV and capacity from 15kVA to 250kVA.Design standards conform to ANSI/IEEE, DOE, CSA, NEMA. Three phase pad mounted transformer the high voltage up to 34.5kV and ratings up to 10 MVA.
Daelim transformer has a strict quality control system to ensure the quality, safety and performance of each transformer.
Click Here Get Transformer Price
Daelim pad mounted transformer has been exported to North and South American markets such as the United States, Canada, Honduras, and El Salvador. Daelim pad mounted transformer is widely used in residential areas, commercial areas, encrypted mining areas, and renewable energy sources such as wind and solar energy, charging piles, etc.


Wind Transformer
Solar Power Transformer
Pad mounted transformer


Recommend Products


2000kVA substation transformer
2500kVA transformer
5000kVA substation transformer


100kVA single phase
pad mounted transformer
75kVA single phase
pad mounted transformer
50kVA Single phase
pad mounted transformer


Radial feed transformer
Dead front transformer
Loop feed transformer


Contact Information


Daelim Transformer
Sales Manager
Tel: 86-1065002471
Email: info4@daelim-electric.com
Phone&WhatsApp: 86-15101594761
www.daelimtransformer.com
www.daelimbelefic.com


0.1617 s.