Steel tent stakes Double Head Tent Stake
US $12.50-$15.00
Share on (1601203739685):
Basic Information | ||
Part Number | 02353AHX | |
Model | S5731-S24P4X | |
Description | S5731-S24P4X (24*10/100/1000BASE-T ports,4*10GE SFP+ ports,PoE+, without power module) | |
Technical Specifications | ||
Chassis material | Metal | |
Height [mm] | 43.6 mm | |
Depth [mm] | 420.0 mm | |
Wide [mm] | 442.0 mm | |
Chassis height [U] | 1 | |
Weight with packaging [kg(lb)] | 8.6 (18.96) | |
Weight without packaging [kg(lb)] | 5.48 (12.08) | |
Maximum power consumption [W] | - Without PoE: 121 W - Full PoE load: 977 W (PoE: 720 W) | |
Typical power consumption [W] | 95 | |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment | |
Maximum heat dissipation [BTU/hour] | - Without PoE: 413 - Full PoE load: 3334 | |
Typical heat dissipation [BTU/hour] | 324.15 | |
Power supply mode | Pluggable power supply | |
Input voltage range [V] | - AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz - High-voltage DC input: 190 V DC to 290 V DC - DC input: –38.4 V DC to –72 V DC | |
Rated input voltage [V] | - AC input: 100 V AC to 130 V AC, 200 V AC to 240 V AC; 50/60 Hz - High-voltage DC input: 240 V DC - DC input: –48 V DC to –60 V DC | |
Maximum input current [A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. | |
Number of power slots | 2 | |
Number of card slots | 0 | |
Memory | 2 GB | |
Flash memory | 1 GB in total. To view the available flash memory size, run the display version command. | |
Redundant power supply | 1+1 Pluggable AC and DC power modules can be used together in the same switch. | |
Types of fans | Pluggable | |
Noise at normal temperature (acoustic power) [dB(A)] | 62.3 | |
Noise at normal temperature (acoustic pressure) [dB(A)] | 52.8 | |
Airflow direction | Air intake from front, air exhaustion from rear (front-to-rear) | |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) | |
Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) | |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). | |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing | |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) | |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) | |
MTBF [year] | 57.21 | |
MTTR [hour] | 2 | |
Availability | > 0.99999 | |
Maximum number of physical ports on the entire device | 28 | |
Maximum number of 100GE ports | 0 | |
Maximum number of 40GE ports | 0 | |
Maximum number of 25GE ports | 0 | |
Maximum number of 10GE ports | 4 | |
Maximum number of GE ports | 28 | |
Maximum number of FE ports | 24 | |
10GE optical interface | 4 | |
1000M electrical interface | 24 | |
USB | Supported | |
Console port | RJ45 | |
Eth Management port | RJ45 | |
Service port surge protection [kV] | Common mode: ±6 kV | |
Power supply surge protection | - Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode - Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode | |
RPS input | Not supported | |
PoE | Supported | |
PoE power supply | Supported | |