Share on (1601240509840):
Model | CI-PC96 |
Measure Range | 0-10/100/1000ppm, 1% O2 |
Principle | Electrochemical |
Measure Mode | Online |
Install | Dial mounted |
Application | Non dangerous general applications |
Sensitivity | 0.5% F.S. |
Measure Accuracy | ≤±5% @ 0-10ppm ; ≤±3% @ 0-100ppm; ≤±2% @0-1000ppm |
Stability | ≤±2.5% @ 0-10ppm; ≤±1.5% @ 0-100ppm; ≤±1% @ 0-1000ppm |
Response Time | T90<60s under 25℃ |
Sample Gas Temperature | 0-45℃ |
Sample Gas Flow | 1.2L/min |
Sample Gas Pressure | 35-210KPa |
Power Supply | AC85~265, consumption lower than 20VA |
Signal Output | 4-20mA DC isolated, with 0-100mV, 0-1V and 0-10V to switch |
Alarms | 2 way SPST alarm |
Alarm Contact Capacity | 0.2A under AC240V |
Display Resolution | 0.01%@%; 1ppm@100-10000ppm; 0.1ppm@10-100ppm; 0.01ppm@0-10ppm |
Communication | RS232 standard (RS485 optional) |
Analyzer Size | 144 (W)×144 (H)×190 (D) mm |