industrial advanced condensing steam turbine
US $1000-$3000
Share on (1601241243476):

》》》Generator of different voltage | ||||||||||||||
Voltage (V) | Frequency (Hz) | Phase | P.F(COS¢) | Standby Amps (A) | Prime Amps (A) | Standby Power (KW / KVA) | Prime Power (KW / KVA) | |||||||
440/254 | 50 | 3 | 0.8 | 288 | 262 | 176 / 220 | 160 / 200 | |||||||
415/240 | 50 | 3 | 0.8 | 304 | 278 | 176 / 220 | 160 / 200 | |||||||
400/230 | 50 | 3 | 0.8 | 316 | 288 | 176 / 220 | 160 / 200 | |||||||
380/220 | 50 | 3 | 0.8 | 334 | 304 | 176 / 220 | 160 / 200 | |||||||
Prime power : | Continuous running at variable load for unlimited periods with 10% overload available for 1 hour in any 12 hour period. In accordance with ISO 8528,ISO 3046. | |||||||||||||
Standby power : | Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. In accordance with ISO 3046 . | |||||||||||||
Prime Voltage : | can be customized according to customer’s requirement. | |||||||||||||
》》》ENGINE DATA | ||||||||||||||
Brand / Model: | CUMMINS 6CTAA8.3-G2 , 4-cycle | |||||||||||||
Air Intake System: | Turbo, Water /Air cooling | |||||||||||||
Fuel System: | PT type fuel pump, EFC Electronic governor | |||||||||||||
Cylinder Arrangement: | "L" type, inline 6-cylinder | |||||||||||||
Displacement: | 8.3 L | |||||||||||||
Bore and Stroke: | 114*135 (mm) | |||||||||||||
Compression Ratio: | 16.5 :1 | |||||||||||||
Rated RPM: | 1500 rpm | |||||||||||||
Max. Standby Power at Rated RPM: | 203KW / 276HP | |||||||||||||
Governor Type: | High-precision electronic speed control system | |||||||||||||
》Exhaust System | ||||||||||||||
Exhaust Gas flow: | 1250 L/s | |||||||||||||
Exhaust Temperature: | 530 ℃ | |||||||||||||
Max Back Pressure: | 10 kPa | |||||||||||||
》Air Intake System | ||||||||||||||
Max Intake Pressure: | 6.23 kPa | |||||||||||||
Consumption: | 762 L/s | |||||||||||||
Air Flow: | 1430 L/s | |||||||||||||
》Fuel System | ||||||||||||||
100%( Prime Power) Load: | 204.6 g/Kw.h | |||||||||||||
75%( Prime Power) Load: | 205.4 g/Kw.h | |||||||||||||
50%( Prime Power) Load: | 215.7 g/Kw.h | |||||||||||||
》Oil System | ||||||||||||||
Total Oil Capacity: | 28 L | |||||||||||||
Oil Consumption: | ≤4 g/kw.h | |||||||||||||
Engine Oil Tank Capacity: | 22 L | |||||||||||||
Oil Min-Pressure at Rated RPM: | 345-483 kPa | |||||||||||||
》Cooling System | ||||||||||||||
Total Cool fluid Capacity: | 40 L | |||||||||||||
Thermostat Temperature: | 82-93 ℃ | |||||||||||||
Max Water Temperature: | 104 ℃ | |||||||||||||
》》》ALTERNATOR DATA | ||||||||||||||
Products comply with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards. | ||||||||||||||
Brand / Model: | FEYDR FYD-W274G | |||||||||||||
Number of Phase: | 3 | |||||||||||||
Connecting Type: | 3 Phase and 4 Wires, “Y” type connecting | |||||||||||||
Amount of Bearing: | 1 | |||||||||||||
Power Factor: | 0.8 | |||||||||||||
Protection Grade: | IP23 | |||||||||||||
Altitude: | ≤1000m | |||||||||||||
Rated Hz: | 50Hz | |||||||||||||
Exciter Type: | Brushless, self-exciting | |||||||||||||
Voltage control mode: | AVR(Automatic Voltage Regulator) | |||||||||||||
Insulation Class, Temperature Rise: | H/H | |||||||||||||
Radio interference: | Meet the BS800 and VDE G、N | |||||||||||||
Telephone Influence Factor (TIF): | <50 | |||||||||||||
Telephone harmonic Factor (THF): | <2% | |||||||||||||
Steady Voltage adjustment rate: | ≤±1% | |||||||||||||
Alternator Capacity: | 160KW / 200KVA | |||||||||||||
Alternator Efficiencies: | 93.80% | |||||||||||||
Standard Temperature Rise: | 125 -163°C Continuous | |||||||||||||
Cooling method: | Direct drive centrifugal blower fan | |||||||||||||
Air Cooling Flow: | 1.035 m³/s | |||||||||||||
》》》DIESEL GENERATING SETS DATA | ||||||||||||||
Voltage Regulation Range: | ≥±5% | |||||||||||||
Steady Voltage adjustment rate: | ≤±1% | |||||||||||||
Instantaneous Voltage Warp (100% Sudden Reduce): | ≤+25% | |||||||||||||
Instantaneous Voltage Warp (Sudden increase): | ≤-20% | |||||||||||||
Voltage Stable Time (100% Sudden Reduce): | ≤6 S | |||||||||||||
Voltage Stable Time (Sudden Increase): | ≤6 S | |||||||||||||
Steady Frequency Reduce rate: | 0-5%(Adjustable) | |||||||||||||
Frequency Waving rate: | ≤0.8% | |||||||||||||
Instantaneous Frequency Warp(100% Sudden reduce): | ≤+12% | |||||||||||||
Instantaneous Frequency Warp (Sudden Increase): | ≤-10% | |||||||||||||
Frequency Recovery Time (100% Sudden Reduce): | ≤5 S | |||||||||||||
Frequency Recovery Time (Sudden Increase): | ≤5 S | |||||||||||||
Emission standard: | Europe Ⅱ | |||||||||||||









New products from manufacturers at wholesale prices