Share on (1601258494979):



Model | SL3.6KLV-W | SL5KLV-W | SL6KLV-W | ||
PV (DC) | |||||
Recommended Max. Py input Power | 5760 Wp | 8000 Wp | 9600 Wp | ||
Max. Input Voltage | 500 V | ||||
Start-up Voltage | 125 V | ||||
Rated Input Voltage | 370 V | ||||
MPPT Input Voltage Range | 150-430 V | ||||
MPPT Max. Input Current | 18 A | ||||
MPPT Short-circuit Current | 20 A | ||||
No. of MPPT | 2 | ||||
No. of Strings per MPPT | 1 | ||||
Grid (AC) | |||||
Max. Input Apparent Power | 7590 VA | 7590 VA | 9200 VA | ||
Rated Output Power | 3600 W | 5000 W | 6000 W | ||
Max. Output Apparent Power | 3960 VA | 5500 VA | 6600 VA | ||
Rated AC Voltage | L/N/PE 230 V | ||||
Input/Output Voltage Range | 180-300 V | ||||
Rated Output Voltage Frequency | 50/60 Hz | ||||
Input/Output Voltage Frequency Range | (45-55)/(55-65)Hz | ||||
Rated Output Current | 15.7 A | 21.7 A | 26.1 A | ||
Max. Input/Output Current | 33 / 17.2 A | 33/23.9 A | 40/28.7 A | ||
Power Factor (Rated) | >0.99 | ||||
Adjustable Power Factor Range | 0.8 leading .. 0.8 lagging | ||||
Total Harmonic Distortion | <3% (Rated Power) | ||||
Grid Connection Mode | L/N/PE | ||||
AC Load Output (off-grid) | |||||
Rated Output Power | 3600 W | 5000 W | 6000 W | ||
Max. Output Apparent Powen | 3960 VA | 5500 VA | 6600 VA | ||
Rated Output Voltage | L/N/PE 230 V | ||||
Output Voltage Range | 200-240 V | ||||
Rated Output Frequency | 50/60 Hz | ||||
Rated Output Current | 15.7 A | 21.7 A | 26.1 A | ||
Max. Output Current | 17.2 A | 23.9 A | 287 A | ||
Total Harmonic Distortion | <3% (Rated Power) | ||||
On-grid/Off-grid Switching Time | 10 ms | ||||
Battery (Dc) | |||||
Rated Output Power | 3600 W | 5000 W | 6000 W | ||
Max,Charge/Discharge Power | 3600 W | 5000 W | 6000 W | ||
Rated Voltage | 48 V | ||||
Battery Voltage Range | 40-60 V | ||||
Max. Charge/Discharge Current | 90 A | 120 A | 135 A | ||
Communication Port | CAN/RS485 | ||||
Efficiency | |||||
Max. Efficiency | 97.6% | ||||
Max. MPPT Efficiency | 99.9% | ||||
Max. European Efficiency | 96.5% | ||||
Protection | |||||
Integrated Protection | Anti-countercurrent Protection: insulation lmpedance Detection: Photovoltaic Reverse Connection Protection.Input DC Switch; GFCl Leakage Current Detection; Output Short-circuit Protection; Output Overcurrent ProtectiorGrid Monitoring; lslanding Protection; Residual Current Detection; Off-grid Overloac | ||||
Surge Protection | DC Type ll, AC Type ll | ||||
Display and Communication | |||||
Display | LCD+LED+APP | ||||
Communication | RS485, WiFi (Optional) | ||||
General Data | |||||
Dimensions (WxHxD) | 492x400x220 mm | ||||
Weight | 21 kg | ||||
Operating Temperature Range | -25°c..60°C(Greater than 45°c Derating) | ||||
Noise | <35 dB | ||||
Cooling | Smart Cooling | ||||
Installation Style | Wal-mounted | ||||
Protection Rating | IP65 | ||||
Warranty | 5 Years | ||||
Standards Compliance | |||||
Grid Connection | IEC 62116,IEC 61727,NRS 097-2-1, IEC 61683 | ||||
Safety Regulation | EN/IEC 62109-1/2 | ||||
Others | EN/EC 61000-6-1/3 | ||||


New products from manufacturers at wholesale prices