Modern Dual Conductor Design With Output Of 150W Per Square Underfloor House Floor Heating Mat

Share on (1601261095200):


Price:$6.91 - $8.21

Quantity:


Product Overview

Description



Best Selling




Product Description


Product Name:
ANLT underfloor heating mat
Width:
0.5m
SQ meter:
0.5㎡ to 15㎡
Cable Spacing:
80mm-100mm
Cable Diameter:
3.5-4mm
Max. Ambient Temp:
30°C
Min. Installation Temp:
5°C
Output:
100W/㎡,150W/㎡ ,200W/㎡(-5% to +10%)
Rated Voltage:
100V-260V
Lead Wire Length:
2.5M(8.2ft)
Cable
Twin Conductor Heating Cable
Conductor Insulation
Advanced Fluoropolymer
Outer insulation
Advanced PVC
Warranty
15 Years






Mat is 0.5m wide (eg. 10sqm mat = 0.5m x 20m linear length)
Our new system consists of a 4mm thin 100w,150w,200w per sqm cable mat which can be rolled out and cut to shape to fit any room. Within the mat is a thin 4mm heating cable which is pre-woven into a 500mm wide glass fibre mesh.The mat should be laid directly under the surface to be heated, pressed down and then tiled over, you may wish to add self-levelling screed or cover it with a thin layer of tile adhesive to ensure that the surface is flat.
You can also purchase a choice of thermostats to complete the kit - standard, or touchscreen digital LCD thermostat, each has a temperature probe to fit under the floor to ensure your room is heated to just the right temperature.
Largest mat size is 15m2. When ordering 16m2 or higher, you will receive 2 mats to meet you required size.
To install, join mats parrellel to thermostat.
Example - 16m2 required = 2x 8m2
Included with mat:
1. 4mm thin 100w,150w,200w/sqm Output Heating Mat
2. Conduit pipe 2.5 metre
3. Installation manual
Included with thermostat:
1. Floor probe lead 2.5 metre
2. Installation manual
Our heating mat is ideal for Bathrooms, Kitchens, Lounges,Dining Rooms and most other areas.


Installation Instructions


Please DO NOT cut, damage or shorten the heating cable!!!!!! Only cut and turn the fiber-glass mesh.
Please DO NOT cross the sensor wire over the heating cable or cold lead wire!!!!!!
Please DO NOT make the heating cables cross or touch!!!!!!
All electrical connections must be performed by a fully qualified and certified electrician!!!










Floor material requirements for installing the ANLT Floor Radiant Heating system



Certificate




  • CE of heating Cable

  • CE of thermostat

CE of heating mat


Exhibition






Company Profile


Experience:
Established in 2009, located in Chengdu, China which is known as "Land of Aboundance", ANLT has proven to be reliable and
trustworthy partners to help all aspects of electric heating for heating, snow-melting, de-icing, de-frosting,etc.
* Years of combined experience in researching and developing electric heating products.
* A factory with over 150 skilled and qualified employees, including experienced R & D engineers, technical experts and sales representatives.
Applications:
We offer an extensive array of services with products being widely used in heating application such as radiant heating for
civil/commercial building, snow-melting, de-frosting and de-icing for roof, gutter, driveway, and drain pipes, warm preservation
for pipes, greenhouse, animal husbandary system etc.






Packing & Delivery




Why electric floor heating systems



Energy Efficient & Low Running Costs
Since electric floor heating systems use a lower temperature than standard radiators or baseboards, heating costs are reduced. Because the heat source is spread throughout the floor, it is more evenly distributed and heated floors provide significantly higher levels of comfort. Anlt electric floor heating systems have a low upfront installation cost and zero maintenance requirements. Why heat the entire house when everyone is in the kitchen? With a smart Anlt design, you can lower your furnace thermostat by as much as 3°F to 5°F degrees.

Comfort & Warm Floors
Anlt heats the whole room, from the floor up. This gives you the luxurious comfort of warm floors, and the benefit of an invisible, inaudible and maintenance-free heating system. Because Anlt systems can be zoned room by room, everyone in the house can set their own levels of comfort, from the basement to the bedroom.

Tailored Temperature Control
4 years ago, we designed our own thermostat: the R9 Smart WiFi Thermostat. Now part of a complete range of proprietary controls, the R9 is the only device specifically made to run and monitor electric floor heating systems. It is 10 times more accurate than its peers and has been designed to fit in the 21st century home. Check out the R9 Smart WiFi Thermostat for heated floors, towel warmers and much more!

Design Freedom
There are no heat vents, no ducts, no pipes, no mechanical room. Our systems give you complete freedom of design when remodeling and building your home. By zoning the Anlt systems in various parts of the house, you can select specific and accurate levels of comfort where and when you need it.

Reduced Dust Circulation and Increased Safety
The radiant heat produced by the system reduces humidity and air circulation, meaning that there are fewer dust mites and allergens in the indoor air. There are also no hot low-level surfaces or hard metal edges, as with radiators, making the system child-friendly.


0.1968 s.