Steel tent stakes Double Head Tent Stake
US $12.50-$15.00
Share on (1601280355344):
Part Number | 02350SRU |
Model | CE6870-48S6CQ-EI |
Description | CE6870-48S6CQ-EI Switch(48-Port 10GE SFP+,6-Port 100GE QSFP28,Without Fan and Power Module) |
Other part numbers | 02350RXD (CE6870-48S6CQ-EI Switch(48-Port 10GE SFP+,6-Port 100GE QSFP28,2*AC Power Module,2*FAN Box,Port-side Exhaust)) 02350RXE (CE6870-48S6CQ-EI Switch(48-Port 10GE SFP+,6-Port 100GE QSFP28,2*AC Power Module,2*FAN Box,Port-side Intake)) |
Installation Type | Cabinet Installation |
Depth [mm] | 420 mm |
Chassis height [U] | 1 |
Wide [mm] | 442 mm |
Height [mm] | 43.6 mm |
Weight without packaging [kg(lb)] | 5.8 kg (12.79 lb) |
Maximum power consumption [W] | 333 W |
Typical power consumption [W] | 159 W (100% throughput, SFP+ high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules) |
Static power consumption [W] | 140 W |
Heat dissipation mode | Air cooling |
Maximum heat dissipation [BTU/hour] | 1135 BTU/hour |
Typical heat dissipation [BTU/hour] | 543 BTU/hour (100% traffic load, SFP+ high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules) |
Static heat dissipation [BTU/hour] | 477 BTU/hour |
Power supply mode | AC,DC |
Rated input voltage [V] | AC power input,Rated input voltage range: 100 V AC to 240 V AC, 50/60 Hz DC power input,Rated voltage range: -48 V DC to -60 V DC |
Input voltage range [V] | AC power input,Maximum input voltage range: 90 V AC to 290 V AC, 47 Hz to 63 Hz DC power input,Maximum voltage range: -38.4 V DC to -72 V DC |
Maximum input current [A] | 600 W AC power module: 100 V to 240 V, 9 A 350 W DC power module: –48 V to –60 V, 11 A |
Rated output power [W] | - 600 W AC power module: 600 W - 350 W DC power module: 350 W |
Maximum output power [W] | - 600 W AC power module: 600 W - 350 W DC power module: 350 W |
Memory | DRAM: 4 GB |
NOR Flash | 16 MB |
NAND Flash | 1GB |
USB | Supported |
Console port | RJ45 |
Downlink Service interface | 48*10GE SFP+ |
Uplink Service interface | 6*40GE/100GE QSFP28 |
Service port supporting the stack function | 10GE and 100GE optical ports |
RTC | Supported |
Switching capacity [bps,bit/s] | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
Redundant fans | 1+1 backup not supported |
Redundant power supply | 1+1 backup |
Number of power modules | 2 |
Power supply surge protection | AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 2 |
Airflow direction | Front-to-back or back-to-front airflow, depending on the selected fan modules and power modules |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating temperature [°C(°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Storage altitude [m(ft.)] | < 5000 m (16404 ft.) |
Long-term operating altitude [m(ft.)] | < 5000 m (16404 ft.) |
MTBF [year] | 54.28 years |
MTTR [hour] | 1.66 hours |
Noise at high temperature (40°C, sound pressure) | Front-to-back airflow: 67 dBA in average (maximum: 73 dBA) Back-to-front airflow: 68 dBA in average (maximum: 75 dBA) |
Noise at normal temperature (27°C, sound pressure) | Back-to-front airflow: < 55 dB(A) Front-to-back airflow: < 51 dB(A) |
Availability | 0.99999651887 |