Share on (1601298395824):
Model | 6-GFM(G)-100Ah | 6-GFM(G)-150Ah | 6-GFM(G)-200Ah | 6-GFM(G)-250Ah | |||
Cells Per Unit | 6 | ||||||
Voltage Per Unit | 12V | ||||||
Capacity | 100Ah@10hr-rate to 1.80V per cell @25°C | 150Ah@10hr-rate to 1.80V per cell @25°C | 200Ah@10hr-rate to 1.80V per cell @25°C | 250Ah@10hr-rate to 1.80V per cell @25°C | |||
Weight | 29kg | 42kg | 58.5kg | 67kg | |||
Internal Resistance | Approx. 6mΩ | Approx. 4mΩ | Approx. 3.5mΩ | Approx. 2.5mΩ | |||
Terminal | F1/F2 | ||||||
Max. Discharge Current | 1500A(5s) | 2250A(5s) | 3000A(5s) | 3750A(5s) | |||
Design Life | 10~15 years | ||||||
Maximum Charging Current | 25A | 37.5A | 50A | 62.5A | |||
Float Charging Voltage | 13.6 V~13.8 V @ 25°C Temperature Compensation: -20mV/°C/Cell | ||||||
Cycle Use Voltage | 14.4 V~14.9 V @ 25°C Cycle Use Voltage Temperature Compensation: -30mV/°C/Cell | ||||||
Operating Temperature Range | Discharge: -20°C~60°C Charge: 0°C~50°C Storage: -20°C~60°C | ||||||
Container Material | A.B.S. UL94-HB, UL94-V0 Optional. | ||||||
Normal Operating Temperature Range | 25°C±5°C | ||||||
Self Discharge | Less than 3% at 25°C per month | ||||||
Container Material | A.B.S. UL94-HB, UL94-V0 Optional |
Specification | GEL 2V 500Ah | GEL 2V 1000Ah |
Cells Per Unit | 1 | 1 |
Voltage Per Unit | 2 | 2 |
Capacity | 500Ah@10hr-rate to 1.80V per cell @25℃ | 1000Ah@10hr-rate to 1.80V per cell @25℃ |
lnternal Resistance | Approx. 1.0mΩ | Approx. 0.6 mΩ |
Terminal | M8 | M8 |
Max. Discharge Current | 2500A(5 sec) | 4000A(5 sec) |
Design Life | 20 years (floating charge) | 20 years (floating charge) |
Maximum Charging Current | 100.0A | 200.0A |
Initial Current | 150.0A MAX | 300.0A MAX |
Reference Capacity | C3 390.0AH C5 432.0AH C10 500.0AH C20 530.0AH | C3 780.0AH C5 865.0AH C10 1000.0AH C20 1060.0AH |
Float Charging Voltage | 2.27V~2.30V@ 25℃ Temperature Compensation: -3mV/℃/Cell | 2.27V~2.30V@ 25℃ Temperature Compensation: -3mV/℃/Cell |
Cycle Use Voltage | 2.42V~2.48V@ 25℃ Temperature Compensation: -4mV/℃/Cell | 2.42V~2.48V@ 25℃ Temperature Compensation: -4mV/℃/Cell |
Operating Temperature Range | Discharge: -40℃~60℃ Charge: -20℃~50℃ Storage: -40℃~60°℃ | Discharge: -40℃~60℃ Charge: -20℃~50℃ Storage: -40℃~60°℃ |
Normal Operating Temperature Range | 25℃± 5℃ | 25℃± 5℃ |
Self Discharge | Less than 3% at 25℃per month | Less than 3% at 25℃per month |
Container Material | A.B.S. UL94-HB, UL94-V0 Optional. | A.B.S. UL94-HB, UL94-V0 Optional. |