Note 1: To prevent situations such as water and gas leakage caused by aging or detachment of pipelines, the pipelines should have corrosion resistance, high temperature resistance, oxidation resistance,pressure resistance, and hydrolysis resistance, The material should have a certain hardness, lt is recommended to use materials such as PTFE (Teflon) for structural components or pipelines, or use medical-grade materials (such as 316L, pure titanium).
Note 2: Please install a temperature probe with over-temperature alarm and shutdown function above the electrolysis cell. The set value should be less than 55'c. To achieve good heat dissipation, there should be sufficient space and optimized channel design around it.
Note 3: Equip the water tank with a liquid level control device (the lowest liquid level of the water tank should not be lower than1.5L).
Note 4:To reduce inappropriate overheating and prevent safety hazards, choose high-quality, compliant, and sturdy electrical components (such as connecting wires, terminal connectors, etc,) and use correct and appropriate connection techniques.
Note 5: lf the electrolysis cell is not used for an extended period, to prevent the internal membrane electrode of the electrolysis cell from being affected by water shortage and affecting the future performance, it is essential to regularly inject pure water that meets the water quality standards into the electrolysis cell and seal all water nozzles with plugs.