Rogowski coil

Share on (1961909117):


Price:

Quantity:


Product Overview

Description


Rogowski coil
1.Diameter:120/190/305
2.Frequency:0-16MHz
3.Test current range:1A-100kA
4.Rated current:0.5-300KA

 

Rogowski Coil

 

A Rogowski coil, named after Walter Rogowski, is an electrical device for measuring alternating current (AC) or high speed current pulses. It consists of a helical coil of wire with the lead from one end returning through the centre of the coil to the other end, so that both terminals are at the same end of the coil. The whole assembly is then wrapped around the straight conductor whose current is to be measured. Since the voltagethat is induced in the coil is proportional to the rate of change (derivative) of current in the straight conductor, the output of the Rogowski coil is usually connected to an electrical (or electronic)integrator circuit to provide an output signal that is proportional to the current.

 

 

 

ModelCategoryAdvantages
FCTNormalLength is up to 20m. Suitable for metallurgy current detection, the detection of leakage current from the super large equipment to the ground and so on. 
FCT-AHigh accuracyAccuracy up to 0.2%. Excellent anti-disturbance, temperature drift and stability.
FCT-FSuper flexibleSuitable for irregular conductor detection, such as the detection of S type output end of transformer.
FCT-HHigh temperature toleranceTemperature tolerance: long time for over 150°, short time for over 200°. Can be used in water or oil.
FCT-MMini rogowski coilDiameter of the coil is down to 4mm. Suitable for current under 1000A, and application with a limitation of space.
FCT-SHigh sensitivityOutput up to 1V/100A. Suitable for leakage/zero-sequence detection, mA level current detection, low-frequency signal (<5Hz) detection.
FCT-TThickerHigh voltage tolerance. Not easy to deformation. Suitable for high voltage, high temperature, and outdoor application.

 

 

 

 

Technical Specification

 

Basic Frequency10Hz .. 10kHzWeight of ElectronicsApprox. 100g
Working Frequency0.8Hz .. 10MHzTransfer Ratio M0.05 .. 10 μH
Linearity<0.01%SensitivityOutput voltage  Vout=2×π×M×f×IAC  
f=frequency   IAC=current to be measured
Measuring Range
(crest factor<1.5@Basic Frequency)
0.01 .. 300kAPhase Error90°± 0.1°
Sensor Cable Length200mm .. 10m
Load Resistance≥1kΩ Sensor Cable Diameter4mm .. 20mm
Operating Temperature -10 .. +60°CSignal Cable Diameter2.0 .. 5.0mm
Storage Temperature  -20 .. +70°CSignal Cable Length0.1m .. 100m
Output ConnectionBanana Plug Pair Output Connection
BNC Output Connetion
OEM Cable Output
Calibration Kit
Special Cable Lengths and/or Gains on request

 

 

Rogowski coil furnace.jpg