Life Jackets Cylinder

  

Key Technical Indexes for 16g CO2 cylinder 

 

Water Capacity:23ml

Filled Gas:CO2
Mass CO2:16+1g
CO2 Purity:≥99.5% H2O≤0.5%
Filling Density:≤0.75g/ml
Burst Pressure of Cylinder:≥56MPa
Test Pressure:65 ,30min
Cap Piercing Force:≤260N
 

Key Technical Indexes for 24g CO2 cylinder 

 

Water Capacity:32ml

Filled Gas:CO2
Mass CO2:24+1g
CO2 Purity:≥99.5% H2O≤0.5%
Filling Density:≤0.75g/ml
Burst Pressure of Cylinder:≥56MPa
Test Pressure:65 ,30min
Cap Piercing Force:≤260N
 
Key Technical Indexes for Manual Inflator
 
The force requires on pull string to activate manual inflator is 13~67N(22N for average value).
 
The string could stand 445N force(3 seconds continuously).

 


0.2025 s.