Share on (50046526686):
This one rogowski coil can monitor AC currents up to 100KAmps. They can be opened and are flexible for ease of installation around bus bars and multiple conductors.They are intended for field installation within distribution and control equipment such as panel boards, switchboards and industrial control equipment to measure the current on branch circuits and feeders. rogowski coil may be used with electric energy meters, or for other current measuring purposes. rogowski coil are different in a few key ways from standard CTs. They do not contain a ferromagnetic core, so they will not saturate, they have excellent linearity, and they have every low phase angle errors. Because they lack a core, it is possible to make them flexible and lightweight. Furthermore, the coil output signal is low voltage (less than one volt AC) and low current (micro amps or less) , so they are safer than ratio CTs. rogowski coil generally require a integrating conditioning circuit, since the output of the coil is the derivative of the actual current. rogowski coil are very dependent on the uniformity of the winding in the sense coil, making them more sensitive to the position of the conductor(s) being measured in the opening and more sensitive to the magnetic fields from external conductors. rogowski coil may provide high accuracy measurement for power frequency current from 100A to 100kA.
Advantages
l Simple to install(especially in limited space)
l Wide dynamic current range
l No magnetic saturation
l No open circuit danger, No overload danger, Intrinsically safe.
l Wide bandwidth
Applications
l Power meters
l Condition monitoring
l Distributed measurement systems
l Electric furnace
l Relay protection
l Grounding current monitoring
l High-Voltage current monitoring CeFlexibleRogowskiCoilCurrentSensor-BuyRogowskiCoil,RogowskiCoilInTransformer,FlexibleRogwoskiCoilProductonAlibaba.com
Type | rogowski coil |
Input | 100A-100KA |
Output(AC and DC) | mV (without integrator); 0-5V,0-10V,0.333v,4-20mA (with integrator) |
Accuracy | <0.8% typical at 10% to 120% of rated current (average position, 25℃) |
Phase error | ≤0.8° |
Linearity | ±0.8% of reading(10% to 120% of range) |
Bandwidth | 1Hz to 1MHz(-3dB) |
Operating temperature | -30℃ to 80℃ |
accuracy | ±1% from 5% to 130% of rated current |
Certificate | CE, Rosh |
Storage temperature | -40℃ to 90℃ |
Diameter | 6-50CM |

1) Very high current monitoring
2) DC ripple measurement
3) Harmonics and transients monitoring
4) Power monitoring & control systems
5) Applicable in eletronic Watt-hour meter
6) Power quality monitoring
7) Electric furnace
8) Harmonic management
9) Relay Protection