wound dressing ,wound care,disposable product

Share on (590385693):


Price:

Quantity:


Product Overview

Description


 


 Product Name:WAYPORE Non-woven dressing


 


1. Intended Use:


The WAYPORE Non-woven dressing is used mainly for protecting surgical injuries or wound. Each piece is packed separately, sterilized and single used. It is soft, ventilate and won’t stick to the injuries. They are designed according to the actual use requirement, and it is no problem to do the special shape and sizes according to the client’s requirement.


 


2. Classification:


According to Annex IX Rule 4 Of the Council Directive 93/42/EEC,it is classified into Class Is.


3.product requirement:


3.1 product Specification :  


 


                









































Item No.



Specification                         (pad size)



Packing



801009


 



5x7



100pcsx20boxes, 2000pcs/ctn



801022


 



8x10



50pcsx24boxes, 1200pcs/ctn



801025


 



10x15



50pcsx12boxes, 600pcs/ctn



801015


 



10x20



50pcsx12boxes, 600pcs/ctn      



801016


 



10x25



50pcs/boxes, 500pcs/ctn



801017



10x30



50pcs/boxes, 500pcs/ctn



 


Other sizes are available according to customer requirement.


 


3.2 Condition of manufacturing


Our WAYPORE Non-woven dressing products are manufactured in Class-100000 clean room.


All aspects of temperature, relative humidity, frequency of air changed, quiescence pressure difference, air particle contamination, air microbiologic contamination etc eligible in the pouch packing room, production room and packing room.


3.3 requirement of the non-woven material


A.weight: 50gsm


B.component: 50%Viscose fibre+50%polyester fibre


C. appearance:  white colour, clear,no flash, without impurity.


 


3.4 character of the adhesive tape


A: Tensile strength:  not less than 20N/25mm in portrait direction


B: Adhesiveness on steel for peeling at 180°: not less than 3.0N/25mm in portrait direction.


C: permanent viscosity(mm): not more than 2.5mm.


 


3.5 dressing layer


A: Liquid absorbability of absorbent pad: not less than 300%


 B: Matter soluable in water: ≤1%


C: Fluorescent material: shall not be strong blue fluorescence


D: Dryness weight loss: ≤15%


E: Acidity and alkaline(PH): within the range 5.5-7.5


 