Medical Diagnostic HIV 1/2 Rapid Test Kit/One Step HIV Home Use Test

Share on (60244533435):


Price:RUB 3.83 - RUB 23.72

Quantity:


Product Overview

Description

Our Adantages

DIAGNOS-01 

Product Descripition

Medical Diagnostic HIV 1/2 Rapid Test Kit/One Step HIV Home Use Test 

Product name

   Medical Diagnostic HIV 1/2 Rapid Test Kit/One Step HIV Home Use Test 

Specimen

Plasma/Serum/whole blood

Format

Cassette/strip

Size

3.0mm/4.0mm

Storage

4-30℃ at room temperature

Shelf life

24 --36 Months

Materials Provided

 

For whole blood test: Alcohol swab, lancet,  cassette, pipette, diluent,( product instuction paper insert )

For Serum/Plasam test: each pouch contains one test cassette and one desiccant ( product instruction insert )

Brand Name

DIAGNOS

MOQ(Minimum order quantity)

2000pcs

Certification

CE/ ISO9001/ ISO13485/FSC

AccuracyOver 99%
Result timeWithin  15 minutes
Packing DetailsStrip: 1pcs/foil pouch ,50 pcs/valve bag, 5000 pcs/carton 
 Cassette: 1pcs/foil pouch ,40 pcs/valve bag, 2000 pcs/carton
Payment methodT/T, Western Union or Paypal are available
Delivery time7--25 days(As your order)
Free samplesAvailable
Other ServiceThe kits can be made according to the customers' artwork or design.

 

 hiv1_hiv test 1 

 

 HIV-4

Related Products

Other Products

Test procedure

Instruction:

In-Vitro high sensitive rapid HIV test Cassette is a single use device,for qualitative detection of antibodies to Human Immunodeficiency Viruses I&II (HIV I&II) in human serum, plasma or whole blood. The Rapid HIV I&II Test Kit provides private at-home HIV testing with fast and reliable result, and at a time when you needed to know the most!

 

Analysis of Results: 

1) PositiveBoth purplish red test band and purplish red control band appear on the membrane. The lower  the antibody concentration, the weaker the test band. 

2) NegativeOnly the purplish red control band appears on the membrane. The absence of a test brand indicates a negative result. 

3) InvalidThere should always be a purplish red control band in the control region regardless of test result . If control band is not seen, the test is considered invalid. Repeat the test using a new test device. 

 

Note: It is normal to have a slightly lightened control band with very strong positive samples as long as it is distinctly visible.

 xians.jpg

About us

About us.jpgOur Ofifice.jpgCertificate

 

product processpackingshippingOur Service

Packing Details : Standard packing ,neutral packing, your requirement are available
Delivery Details : 
7-25 days after receiving the 30% deposit

Shipping Details : DOOR TO DOOR, BY AIR, BY SEA etc.
Payment Details :
T/T,Western Union and Paypal are available.

After service:

 1.Service tenet: quick and decisive and thoughtful thorough and accurate;

2.Service objectives: service quality to win customer satisfaction;

3.Service efficiency:   We will have a dedicated staff to detect problems with the product for testingf  if you are not satisfied when you receive your goods, and promptly get back to you within 24 hours.

4.Service principles: products in the course of product issues caused by improper operation, we will provide a solution.

FAQ

Q1.What's the method you use to do the test?

A: Colloidal Gold Method.

Q2: What's ur MOQ ?
A: Always, for strip format, the MOQ is 2000pcs. While for cassette format, MOQ is 2000pcs, same as midstream.  

Q3: What's ur packing of the tests?
A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.

Q4: What's the main differences when comparing products from different suppliers?
A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.

Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.

Q6: How can i distinguish a good test kit?
A: U can judge from the 4facts: 
1. Technical data: Such as the accuracy, specificity and sensitivity.
2. Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.
3. Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.
4. Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice.

0.187 s.