Women Rapid Sensitive Fertility Test(LH/FSH/HCG Test)


Size:


strip: 2.5mm,3.0mm,3.5mm,4.0mm


cassette: 3.0mm,4.0mm


midstream: 4.5mm,5.5mm,6.0mm


Test Procrdure


1.To begin testing; open the sealed pouch by tearing along the notch.. Remove the test form the pouch.


2.Immerse the strip into the urine with the arrow end pointing towards the urine. Do not immerse past the MAX  (maximum) line. Take the strip out after 3 seconds and lay the strip flat on a clean, dry, nonabsorbent surface (e.g., mouth of the urine container).


3.Wait for colored bands to appear. Depending on the concentration of HCG in the test specimen, positive results may be observed in as short as 40 seconds. However to confirm negative results, the complete   reaction time (5 minutes) is required. Do not read results after 10 minutes.


 


 


 


 


ZZ@)WRVU[}([}BEI98$7SME.jpg 


 


 


 


INTERPRETATION OF RESULTS:


1. Negative: 


Only one color band appears on the control region. No apparent band on the test region. There is no pregnancy.


 


2. Positive: 


Distinct color bands appear on the control and test regions. Beth test line and control line indicate that you are pregnant. 


Color intensity of the test bands may vary. Different stages of pregnancy have different concentrations of HCG hormone.


 


3. Invalid: 


No visible bang at all. Repeat test with a new test kit.


 


 


STORAGE AND STABILITY:  


  


The test kits can be stored at room temperature (18 to 30°C) in the sealed pouch to the date of expiration. The test kits should be kept away from direct sunlight, moisture and heat. the desiccant is not used in the test.


 


 


PRECAUTION


 


1.For in vitro diagnostic use only.


2.Do not use test kit beyond expiry date.


3.The test device should not be reused.


 


 


2.jpg


hcg card


IMG_0506.jpg


3.jpg



Related Products


















Other Products


















Packaging & Shipping


shipping_shipping 





contact us


Tina card.png 





FAQ




Q1: What's the method u use to do the test?


A: Colloidal Gold Method.

Q2: What's ur MOQ ?
A: Always, for strip format, the MOQ is 1000pcs. While for cassette format, MOQ is 1000pcs, same as midstream. 

Q3: What's ur packing of the tests?
A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.

Q4: What's the main differences when comparing products from different suppliers?
A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.

Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.

Q6: How can i distinguish a good test kit?
A: U can judge from the 4facts: 
1. Technical data: Such as the accuracy, specificity and sensitivity.
2. Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.
3. Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.
4. Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice.