Share on (60371835533):
Beer keg washing filling unit machine 
1, Specification
table-board size | 1200mm×450mm |
table-board height | 700mm |
exterior dimension | 1200mm×1400mm×1900mm |
cylinder max stroke | 300mm |
net weight | 260Kg |
power | 18KW |
Heating | (electrical heating) 220V three-phase |
capacity | 20~40kegs/hour |
cleaning mode | keg topside down |
applicable keg | diameter φ250~φ500, height 360mm~600mm |
2, Technical parameter
air source pressure | 0.6~0.7Mpa |
CO2 source pressure | 0.3~0.4Mpa |
cylinder valve pressure | 0.5~0.6Mpa |
CO2 valve pressure | 0.2~0.3Mpa |
Air-blow valve pressure | 0.2Mpa |
sterile water pressure | 0.4Mpa |
power voltage | Three-phase 220V 60Hz |
3. Main Structures and Features
This machine mainly contains the frame, electric system, air system and other pipeline system. The features are as below:
1. All parameters (time values) can be adjusted without stopping the machine.
2. Maximum straight-line design on main cleaning pipelines makes sure the powerful and thorough scouring.
3. Twin-acting pneumatic valve with reliable quality and anti-high temperature characteristic.
4. Adoption of world top products as main accessories makes sure premium quality.
5. The sterile water and the lye water can be recyclable.
4. Working Procedures
Load the keg → start (cylinder pressing tightly) → air blowing (draining residue) → scoured by clean water → air blowing (draining water) → scoured by lye water → extracting tube scoured by lye water → air blowing and recycle → scoured by clean water → extracting tube scoured by clean water→ air blowing (draining water) → scoured by clean water → air blowing → scoured by sterile water → air blowing → prepare CO2 pressure → reset the cylinder → unload the keg
beer kegs Filling machine



5. Usual Malfunction and Removing Method
Malfunction | Possible reason | Moving method |
Leakage of cleaning head | loose cylinder | check the cylinder pressure |
incorrect orientation | orient the keg correctly | |
loose gasket | Adjust gasket | |
Power disconnection of PLC | incorrect voltage value | check the power |
high ampere value(≥3A) | check the circuit | |
Extinguishing of indicator | Indicator damage | change the indicator |
Remaining liquid in keg after cleaning process | insufficient air-blowing time | adjust air-pumping time |
damaged extracting tube | change extracting tube | |
Virus standard unconformity | expired disinfectant | change disinfectant |
Welcome to your inquiry!