Share on (60449778484):
The total weight of solenoid (with two solenoids) | kg | 0.89 |
The total weight of solenoid (with one solenoids) | kg | 0.72 |
Installation site | Optional position | |
Operating temperature | ℃ | -20~+50(adopt NBR seal ring ) |
Maximum working oil pressure P,A and B | MP a | 31.5 |
The highest oil pressure T cavity can bear | MP a | 18 |
Maximum flow | 1/min | 20 |
Liquid medium | Mineral hydraulic oil, Phosphate hydraulic oil | |
The oil temperature range | ℃ | -20~+80 |
The oil cleanliness | ISO4572:β10≥75NAS1638:Class 9 | |
The oil viscosity | ISO-VG32(5420)cst |
Voltage category | DC,RAC(coil with a rectifier component) | |||||||||||
Working system | ED | 100% | ||||||||||
Allowed voltage fluctuation range | % | -10~+10 | ||||||||||
The reserving and reset time | ms | On50…90 off40…80(do not include RA type) | ||||||||||
Maximum reversing rate | Hz | 3 | ||||||||||
Coil insulation class | H | |||||||||||
The maximum operating temperature coil allowed | ℃ | 180 | ||||||||||
Coil weight | kg | 0.215 | ||||||||||
voltage | V | 12 | 24 | 48 | 110 | R110 | R220 | |||||
Power types | DC | DC | DC | DC | AC | AC | ||||||
Power rate | Hz | -- | -- | -- | -- | 50/60 | 50/60 | |||||
Power consumption | W | 26 | 26 | 26 | 26 | 29 | 29 | |||||
Coil resistance(20℃) | ohm | 2.18 | 1.10 | 0.50 | 0.26 | 0.33 | 0.17 | |||||
Operating current(20℃) | A | 5.5 | 22 | 89 | 413 | 89 | 413 |
New products from manufacturers at wholesale prices