Share on (60453756310):
veterinary Feline Immunodeficiency and Feline Leukemia combined rapid test
Why choose us?

Our Advantage:
1.Our Rapid test series enables the detection of very low viral loads, from the end of the incubation period.
2.Our Rapid test series is a quick and easy diagnostic tool that can be performed during a consultation in just 10 minutes.
3.The accuracy is over 99.9% .
4.We have experience of manufacture for various rapid test kit.
5.Our customers are all over the world ,so you will get the most professional service.
6.We are the golden supplier of Alibaba, and we are the long-term top supplier of globalsources.
7.We have lots of Rapid test series for you reference and choosing.
8.If you have any request,email us,you will get the quickest reply.
Principles
The test device is an immunochromatographic assay for the qualitative detection of CAV Ag and CDV
Ag in canine respiratory tract secretions. The test device has a letter of “T” and “C” as test line and
control line on the surface of the card. Both the test line and control line in result window are not visible
before applying any samples. The control line should be always appear if the test procedure is performed
properly and the test reagents of control line are working. A purple test line will be visible in the result
window if there are enough Antigen in the specimen. The specially selected monoclonal antibodies are
used in test band as both capture and detector materials. These enable the device to identify CAV Ag and
CDV Ag in canine with a high degree of accuracy.
Characteristics
1) One-step rapid test of CAV Ag and CDV Ag
2) Rapid test results between 5 ~ 10 minutes
3) Expensive equipment not required
4) Easy storage and maintenance
5) High-purity and high-quality materials of the test kit increase its sensitivity and specificity.
Materials (10 tests/kit)
1) Test ----------------------------------------------------------------------------------------------------- 10 units
2) Diluent (buffer) ---------------------------------------------------------------------------- 0.4 x 10 units
3) Disposable dropper --------------------------------------------------------------------------------- 10 units
4) Swabs for sample collection ------------------------------------------------------------------------- 10 units
Composition
Specimen well (S: for dropping), Test line (T), and Control line (C) are marked on the device. Inside of
it, the strip is composed of sample pad, conjugate pad, nitrocellulose membrane (test paper), and
absorbent pad
Effect
Simultaneous detection of CAV Ag and CDV Ag in Canine ocular discharge or nasal discharge
Uses
1) Specimen
Canine ocular discharge or nasal discharge
2) Test procedure
a) Collect canine ocular or nasal discharge with a swab and put the swab into a sample tube
containing 0.4 of buffer.
b) Swirl the buffer with the swab.
c) Drop 4 drops (100 ) into the specimen well.
d) Read the test results within 5 – 10 minutes.
Invalid result after 10 minutes.
3) Interpretation of the results
A purple band should appear on the control line regardless of the test result. The presence of
another band on the test line determines the result.
Control Line (C): The line should always appear. If this line does not appear, the test should be
considered invalid. This is might be because of impure buffer or the lack of
specimen. It should be tested again with another kit.
Test Line (T): The presence of CAV Ag / CDV Ag determines the test line.
(1) CA V Negative / CDV Negative
(2) CAV Positive / CDV Negative
(3) CAV Negative / CDV Positive
(4) CAV Positive / CDV Positive
4) Retesting
a) Both Test and Control lines do not appear.
b) Test line only appears.
.
Further examinations
This test is for primary screening only . Co nsult veterinarians for further necessary examinations to
obtain clinical test results.
Precautions
1) Use for canine in-vitro diagnostic purposes only.
2) Use within 10 minutes after opening the pouch because the test kit is very sensitive to moisture and its
effect may diminish.
3) Be careful of not touching the result window.
4) Every specimen should be used with different dropper.
5) For testing, buffer included only should be used.
6) Do not use specimen showing hemolysis or being contaminated with microbes, which may cause false
positive or false negative result.
7) Deal with specimen carefully. They can deliver unknown virus or infectious bacteria.
8) Use disposable gloves when you suspect the infection caused by specimen. And wash your hands later.
9) Dispose solid wastes after sterilizing them at 121 °C for over 1 hour.
10) Do not use the kit when its pouch is torn, sealing is not good shape or expiration date is passed.


Minimum Order Quantity: | 50 Box/Boxes |
Packing size: | 10 tests/Box |
Supply Ability: | 30000Box/Boxes per Week |
Payment Terms: | T/T,Western Union |
Packaging Details: | 10 pouches/10 tubes ,10 single packed swabs 10 test/box, 50boxes/ctn, 7.7kg/carton,Measurement: 515*295*425 mm |
Delivery Detail: | 3 - 5 working days upon receipt of payment |
Delivery Port | Shang hai/Wuhan |


1. Any inquiries will be replied within 24 hours
2. Professional manufacture.
3. OEM/ODM are available
1) Customized design foil bag and Customized design box
2) White foil bag and white box and print lable in box
3) Uncut sheet is available
4) Handle label is available
5) Any your idea on rapid test we can help you to design and put it into production
4. High quality. reasonable and competitive price,fast lead time
5.After-sale service
1)All products will have been strictly Quality checked in house before packing
2)All products will be well packed before shipping
3)All our products have 18 month expiration date.
6.Faster delivery
sample order in stock,and 3~15 days for bulk production
7. Payment: You can pay for the order via: T/T Western Union
8.Shipping: We have strong cooperation with DHL,Fedex,TNT,EMS,China Air port




New products from manufacturers at wholesale prices