Share on:
Inverter Output | Model | 1kw | 1.5kw | 2kw | 3kw | 4kw | 5kw | 6kw | 8kw | 10kw | 12kw | 15kw | 18kw |
Continuous Output Power | 1kw | 1.5kw | 2kw | 3kw | 4kw | 5kw | 6kw | 8kw | 10kw | 12kw | 15kw | 18kw | |
Surge Rating (20Secs) | 3kw | 4.5kw | 6kw | 9kw | 12kw | 15kw | 18kw | 24kw | 30kw | 36kw | 45kw | 54kw | |
Output Waveform | Pure Sine wave/Same as input (Bypass Mode ) | ||||||||||||
Nominal Efficiency | >88% (Peak) | ||||||||||||
Une Mode Efficiency | >95% | ||||||||||||
Power Factor | 0.9-1.0 | ||||||||||||
Nominal Output Voltage rms | 100-110-120Vac / 220-230-240Vac | ||||||||||||
Output Voltage Regulation | ±10%RMS | ||||||||||||
Output Frequency | 50Hz±0.3Hz/60Hz±0.3Hz | ||||||||||||
Short Circuit Protection | Yes( 1 sec after fault) | ||||||||||||
Typical transfer Time | 10ms (Max) | ||||||||||||
THD | < 3% (Rated battery level, rated full linear load) | ||||||||||||
DC Input | Nominal Input Voltage | 12Vdc/24Vdc | 12Vdc;24Vdc;48Vdc |
24Vdc 24Vdc/48Vdc 48Vdc/96Vdc |
48Vdc/96Vdc | ||||||||
Minimum Start Voltage | 10Vdc/ 10.5Vdc for 12Vdc Mode | *2 for 24Vdc;*4 for 48Vdc;*8 for 96Vdc; | |||||||||||
Low Battery Alarm | 10.5Vdc /11Vdc for 12Vdc Mode | ||||||||||||
Low Battery Trip | 10Vdc/ 10.5Vdc for 12Vdc Mode | ||||||||||||
High Voltage Alarm | 16Vdc for 12Vdc Mode | ||||||||||||
Low Battery Voltage Recover | 15.5Vdc for 12Vdc Mode | ||||||||||||
Idle Consumption-Search Mode | < 25W When Power Saver On. ( Refer to Table ) | ||||||||||||
Charger | Output Voltage | Depends on battery type (Refer to Table 2.5.2) | |||||||||||
Charger Breaker Rating | 20A | 20A | 20A | 25A | 32A | 40A | 40A | 50A | 80A | 80A | 100 A | 125A | |
Max Charge Power Rate | 1/3 Rating Power ( Refer to Table 2.5,3) | ||||||||||||
Battery Initial Voltage for start | 10-15.7Vdc for 12Vdc Mode | *2 for 24Vdc;*4 for 48Vdc;*8 for 96Vdc; | |||||||||||
Over Charge Protectoon S.D. | 15.7Vdc for 12Vdc Mode | ||||||||||||
Battery Type Selector | Switch Setting | Description | Fast Mode / VDC | Float Mode/ VDC | |||||||||
0 | Charger Off | ||||||||||||
1 | Gel USA | 14.0 | 13.7 | ||||||||||
2 | AGM 1 | 14.1 | 13.4 | ||||||||||
3 | Lithium | 13.8 | 13.6 | ||||||||||
4 | Sealed Lead Acid | 14.4 | 13.6 | ||||||||||
5 | Gel EURO | 14.4 | 13.8 | ||||||||||
6 | Open Lead AckJ | 14.8 | 13.8 | ||||||||||
7 | LifePO4 | 14.0 | 13.8 | ||||||||||
8 | De-sulphation | 15.5 (4 Hours then Off) | |||||||||||
9 | Classic LFP | 13.6 | 13.5 | ||||||||||
For 12Vdc Mode Series(*2 for 24Vdc Mode;*4 for 48Vdc Mode;*8 for 96Vdc Mode) | |||||||||||||
BTS | Battery Temperature Sensor (Optional) |
Yes (Refer to the table) Variances in Charging Voltage & S.D Voltage Base on the Battery Temperature. |
|||||||||||
Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) | |||||||||||
Nominal Voltage | 100-110-120Vac/ 220-230-240Vac | ||||||||||||
Max Input AC Voltage | 150Vac For 120Vac LV Mode : 300Vac For 230Vac HV Mode: | ||||||||||||
Nominal Input Frequency | 50Hzor60Hz | ||||||||||||
Low Freq Trip | 47±0.3Hz for 50Hz 57±0.3Hz for 60Hz | ||||||||||||
High Freq Trip | 55±0.3Hz for 50Hz 65±0.3Hz for 60Hz | ||||||||||||
Bypass Breaker Rating | 20A | 20A | 20A | 25A | 32A | 40A | 40A | 50A | 80A | 80A | 100A | 125A | |
Transfer Switch Rating | 30Amp for UL&TUV | 40Amp for UL | 80Amp for UL | 100Amp for UL | |||||||||
Max Bypass Current | 30Amp | 40Amp | 80Amp | 80Amp | |||||||||
Mechanical Specifications | Mounting | Wall Mount | |||||||||||
Inverter Dimensions (L*W*H) | 388*415a200mm | 488M415*200mm | 588*415*200mm | 688*415-230mm | |||||||||
Inverter Weight (Solar Chg) KG | 23 | 24 | 26 | 30 | 41 | 51 | 53 | 63 | 69 | 73 | 78 | 81 | |
Shipping Dimensions(L*W*H) | 550*520*310mm | 650*520*310mm | 750*520*310mm | 850*520*350mm | |||||||||
Shipping Weight (Solar Chg) KG | 26 | 27 | 29 | 33 | 44 | 54 | 56 | 66 | 72 | 76 | 81 | 84 | |
Display | Status LEDs / Status LEDs+LCD | ||||||||||||
Standard Warranty | 1 Years |
Q1.How is your product quality?
A: QC regularly check the quality.Our products were damaged less than 3% over the past five years. Regarded as a high quality inverter supplier.
Q2.When the product have problem, how to solve it?
A:We have a professional after-sales team, in case of any problems, first contact us to help you solve,
we have a 12 months warranty.We will track product usage until you are satisfied.
Q3.Can you accept OEM, ODM service?
A:Yes, we accept OEM,ODM service.
Q4.What kind of certificate you have ?
A:Our company already achieve ISO, CCC, and for products, we have CE, ETL, UL .
Q5. what's the payment term?
A: We accept TT,50% deposit and 50% before delivery.( >10000$US )
Q6. How's the delivery time ?
A: Usually it will take about 25-35 workdays for production.( >5pcs )