45KW Frequency Converter 380V 415V 480V 575V 690V 3Phases AC Drive VFD Pump Fan 55KW General 45KW motor Variable speed drive

Share on (60482153096):


Price:

Quantity:


Product Overview

Description


45KW Frequency Converter 380V 415V 480V 575V 690V 3Phases AC Drive VFD Pump Fan 55KW General 45KW motor Variable speed drive

 

1. All-purpose general vector driver according to IEC61800 standard

2. Modbus protocol and RS485 interface

3 Unique VTC vector torque control technology makes out superior torque, realizing 150% of torque at 1Hz.

4. Built in braking transistor, over 18.5KW built-in input filter unit.

5. Protective grouding, built-in surge restraint unit, stall prevention, failure reset and restart after instant stop full protection

6. Multi-speed running (max eight speeds), Up/Down running, Jog running

7. Internal PID function realizing high performance closed loop control

8. Slip compensation, over torque detection, speed search convenient fuctions.

9. Multi-function input terminal, 0-10V 4-20mA, 0-20mA analogue monitor

10. Book design, easy installation and wiring.

11. LCD or LED operating panel with parameter copy function, convenient batch debugging and maintenance.

 

TYPESuitable Motor
(General)
Output Current
(General)
Suitable Motor
(Pump)
Output Current
(Pump)
InputOutput
NTL00D4G23A0.4KW3.2A--1Phase
3Phase
220V
50/60Hz
3Phase
220V
0.1-400Hz
NTL0D75G23A0.75KW6A--
NTL01D5G23A1.5KW8A--
NTL02D2G23A2.2KW11A--
NTL03D7G23A3.7KW17.5A--3Phase
220V
50/60Hz
3Phase
220V
0.1-400Hz
NTL05D5G23A5.5KW25A7.5KW-
NTL07D5G23A7.5KW33A11KW-
NTL0011G23A11KW49A15KW-
NTL0015G23A15KW64A18.5KW-
NTL18D5G23A18.5KW80A22KW-
NTL0022G23A22KW96A30KW-
NTL0030G23A30KW130A37KW-
NTL0037G23A37KW160A45KW-
NTL0045G23A45KW183A55KW-
NTL0055G23A55KW224A75KW-
NTL0075G23A75KW300A90KW-
NTL0D75G43A0.75KW3.4A--3Phase
380V
50/60Hz
3Phase
380V
0.1-400Hz
NTL01D5G43A1.5KW4.8A--
NTL02D2G43A2.2KW6.2A--
NTL03D7G43A3.7KW8A--
NTL04D0G05D5P43A4.0KW11A5.5KW14A
NTL05D5G07D5P43A5.5KW14A7.5KW18A
NTL07D5G0011P43A7.5KW18A11KW27A
NTL0011G0015P43A11KW27A15KW34A
NTL0015G18D5P43A15KW34A18.5KW41A
NTL18D5G0022P43A18.5KW41A22KW52A
NTL0022G0030P43A22KW52A30KW65A
NTL0030G0037P43A30KW65A37KW80A
NTL0037G0045P43A37KW80A45KW96A
NTL0045G0055P43A45KW96A55KW128A
NTL0055G0075P43A55KW128A75KW165A
NTL0075G0090P43A75KW165A90KW185A
NTL0090G0110P43A90KW185A110KW224A
NTL0110G0132P43A110KW224A132KW260A
NTL0132G0160P43A132KW260A160KW302A
NTL0160G0185P43A160KW302A185KW340A
NTL0185G0220P43A185KW340A220KW450A
NTL0220G0250P43A220KW450A250KW470A
NTL0250G0280P43A250KW470A280KW520A
NTL0280G0315P43A280KW520A315KW605A
NTL0315G0350P43A315KW605A350KW640A
NTL0350G0400P43A350KW640A400KW690A
NTL0400G0450P43A400KW690A450KW775A
NTL0450G0500P43A450KW775A500KW860A
NTL0500G0560P43A500KW860A560KW950A
NTL0560G0630P43A560KW950A630KW1100A

 

 

Specifications   

FrequencyInput Frequency50/60Hz
Output Frequency0.1-400Hz
VoltageInput Voltage200-230V/380-460V
Output Voltage220V/380V
Control 
characteristic
Control modeCurrent Vector Control, SVPWM, V/F control
frequency range0.1 ~ 400Hz
Frequency precisiondigital: ±0.01%( -10+40 )
analogue:highest frequency× 0.2%Hz ( 25 ±10% )
Frequency settingdigital: 0.01 Hz
analogue: highest frequency × 0.1%Hz
Output detinition0.01 Hz
Over load capacitygeneral type: 150% of rated output current per minute
exhaust fan,water pump:120% of rated output current per miniute
Frequency setting signal0~+10V(20kΩ), 4~20mA(250Ω)
Speed up and down0.0~3600second  (setting speed up and down seperately)
Brake rotation moment125%with braking resitance,20%without
V/f mode15 presetting VF and programing VF
Protection
function
Overload protectionelectronic overheat relay protection
Instantaneous over current flowgeneral typeG:250% of inverter rated current flow
exhaust fan,water pumpP: 200% of inverter rated current flow
Over loadGeneral type G: motor stops after 1 minute of 150% rated current flow exhaust; Fan,water pump type P: motor stops after 1minute of 120% rated current flow.
Over voltagerectifier output 380V(200V grade)/760V(400V grade) or lower, motor stops.
Low voltagerectifier reduce output to 190V(200V grade)/380V(400V grade)or lower, motor stops.
Instantaneous power offinstantaneous power off over 15 ms or over, stop running it keep running when instantaneous power off less than 2 second.
Radiator overheatthermal resistance protection.
Speedless protectionspeedless protection during constant speed or speed up and down.
Grounding problemprotected by electronic circuit.
EnvironmentTemperature humidity-10~+40, 90% relatively.
placeIndoor (avoid dust and corrosive gas).
elevationbelow 1000 meters.
vibrationbelow 0.5G

 

Wiring Diagrams:

3.jpg

4.jpg5.jpg


0.1925 s.