High quality cheap server room steel dampers perforated raised floor

Share on (60623092684):


Price:$18.00 - $25.00

Quantity:


Product Overview

Description


Product Description

High quality cheap server room steel dampers perforated raised floor  

Possess ventilation function,Prevent static validly; fireproof, dustproof

Product details

Product NamePerforated panel
CertificateISO9001
Size600*600mm
CoveringHPL/PVC/Ceramic
ApplicationData Center
Packpaper box/wooden pallet
Colorblack/grey
Product Materialsteel
Functionairflow
UsageComputeroom
Product Keywordsserver room steel perforated raised floor with dampers CHINA

 


 

Description:

BASIC Anti-static perforated panels are designed to computer rooms for airflow.Basic are able to supply perforated panels of different airflow volumes according to different requirements from the customers. Meanwhile,dampers can be applied to perforated panels, so as to control the volume of airflow.

To meet different needs from customers, Basic also supply various kinds of round outlet boxes, square outlet boxes, panels tuyeres, panel lifters and pedestals of different raised height.

 

Features:

1.)      Size: 600*600*35mm

2.)      full steel , HPL or PVC punched tile

3.)     surface punched panel which is hard steel of Shanghai Bao steel,

4.)      Manual welding for the bottom square tube, origination in domestic.

5 )     Imported paint, anti-rust.

6.)    prevent static validly fireproof, dustproof

7.)      exact dimension for the hole of tile and panel ,good ventilation function

8.)     17%~50% ventilation rate, satisfies different environmental requirements

 

Installation: 

1.Requirements to laying site:

1)The laying of antistatic raised access floor shall be carried after the indoor civil engineering and decoration and finished.

2)Ground must be flatness,clean,dry and there shall be no any sundry or dust on it .

3)The construction of cable electric appliance,air pipeline and AC system to be arranged under floor surface shall be finished before the installation of floorings.

4)The base of heavy equipment must be firmed,equipment is installed on the base and the base height shall be align with the upper surface of the floor.

5)The construction site must be equipped with 220V/50HZ power supply and water supply.

 

2. Tools for installation:

Infrared ray level instrument, large push cutter, aluminum alloy ruler, level bar electric hand drill, Mini type marble cutter, pulling nail gun, wire-cutter, steel ruler, nail, pencil, suction disc machine, adz-eye hammer, spanner, screwdriver, floor glue, tool bag ,broom.

 

3. Construction Procedures:

1)The flatness of floor and the verticality of wall are carefully checked. If any part is found not to be consistent with construction requirements,it shall be reported to relevant department of Part A.

2)The horizontal lines are pulled and fixed and the installation height of floorings is drawn on the wall using ink line.The floor panels shall be on a same horizontal plane. The indoor length and width are measured. The reference position of laying shall be selected properly in order to decrease the cutting the floorings.

3)The pedestals to be installed are adjusted to a same height as required,and then placed on the decussation position of the grid lines.

4)Stringers are fixed on the pedestals using screws, and every are on a same plane and mutually perpendicular.

5)The floor replaced on the assembled stringers using board sucker.

6)If the rest distanceto the wall is less than the length of floor , the floor can be cut into adequate size before installation.

7)During the laying of floorings,blister gradienter shall be used for levelling and the height of floorings can be adjusted through pedestal.

8)In case that heavy equipment is placed in machine room,additional pedestal shall be installed under the equipment base in order to avoid the deformation of floorings.

9)If it is necessary to cut or open hole on the raised floor,electrical drill shall be used to open in order to avoid the rupture of veneer.

 

 4. Acceptance criteria for the laying of floorings:

1)Either under the floor or the surface of the floor shall be cleaned,to avoid the dust .

2)There is no search and coating peeling on floorings,and regulas are not damaged.

3)The whole of the floor after laying shall be stable and firm. There is no sound and the feeling of shaking when walking on the floor.

4)The regulas must be in a line,and the displacement of adjuacent regulas shall not be more than 1mm.

5)The height difference of adjacent floor panels shall be more than 2 mm.

 

5.Maintenance Requirements:

1)It is forbidden to directly use sharp tools to carry out construction on the floor surface in order to avoid the damages to the appearance and antistatic performance of flooring surface.

2) During application, no person is allowed to jump onto the floor from high position, and it is forbidden to crudely remove equipment as such operation may damage the floor.

3)When equipment is moved on the antistatic raised access floor,it is forbidden to directly pull the equipment on floor as it may scuff the floor,the equipment shall be lifter before moving.

4)When heavy equipment is to be installed in machine room,it ahall directly place the heavy equipment on floor as deformation may be long-term load bearing.

5)To repair the equipment under the floor, panel lifter shall be first used to remove flooring.It is forbidden to use sharp tools to crudely dismantle and assemble the flooring.

6)During maintenance,dust collector or mop can be used to keep the floor clean. Particularly, measures shall be taken to avoid sprinkling liquid onto floor.

7)Antistatic wax can be polished on the floor surface, in order to protect the floor and ensure the application effect in long time.

 

6.Opetaing Environment:

The temperature in the room to be laid with antistatic raised floorings shall be 15-35degree,and the relative humility is 45%-75%RH.If the humidity of the computer room is low for a long time,there may be cracks on the floor surface and the strength and the thickness of attaching veneer shall be increased therefore.

Company Information

-1_02.jpg-1_03.jpg 

Packaging & Shipping

-1_05.jpg 

FAQ

Are you a trade company or manufacturer factory ?

We are the manufacturer factory.

How many types of products do you have ?

We have anti-static steel cementitious floor, oa bare finish access floor,electrical floor box, brush grommet, woodcore floor,calcium sulphate and raised floor accessories.

Where do the raised floors use ?

All our products are widely used in data center rooms , modern office buildings,schools, hospitals,hotel,etc.

Which countries do your products sell to ?

All over the world, especially in Qatar, South America,etc.

What Port is near to your factory ?

Our factory is located in Changzhou City, near to Shanghai.      

Contact Us

-1_07.jpg 


0.265 s.