Explosion Proof Low Temperature Methanol Chiller For Oil and Gas Recovery System

Share on (60632930762):


Price:

Quantity:


Product Overview

Description


Product Description

Explosion Proof Low Temperature Methanol Chiller For Oil and Gas Recovery System


Oil and gas recovery is a high-tech energy saving and environmental protection, the use of oil and gas recovery technology in oil storage and transportation, loading and unloading of emissions in the process of oil and gas, to prevent air pollution caused by volatile oil and gas, to eliminate potential safety problems, by improving the utilization of energy, reduce economic losses, resulting in considerable returns. At present, there are some common methods such as adsorption, absorption, condensation and membrane separation.

Here we talk about condensation method:
The heat transfer of oil and gas from the gas phase to the liquid phase is achieved by the use of refrigeration technology. Condensation method is the use of hydrocarbon substances at different temperatures of the vapor pressure difference, through the cooling of oil and gas to make some of the hydrocarbon vapor pressure over saturation state, supersaturated steam condensed into liquid, recovery of oil and gas. General multistage continuous cooling method to reduce oil and gas temperature, the condensed liquid recovery, according to the volatile gas components and recovery requirements and finally discharged to the concentration of organic compounds in the atmosphere in the exhaust limits, to determine the minimum temperature of the condensing unit. Generally according to pre cooling, mechanical refrigeration and other steps to achieve. The pre cooler is a single-stage cooling device, in order to reduce the operation energy recovery device, has developed a cold recycling technology, so that the inlet gas temperature recovery device from ambient temperature dropped to 4 degrees Celsius, make the most of water vapor in the gas condenses into water and remove. The gas enters the shallow cooling stage from the pre cooler. The temperature of the gas can be cooled to 30 DEG C - 50 DEG C, and the hydrocarbon material in the oil and gas can be recovered according to the requirement. The oil and gas from the shallow cold can enter into the cryogenic stage, and can be cooled to 73 DEG C to - 110 DEG C.

\t
Item
\t
Specifications
\t

Cooling Capacity
\t
Model
\t
AYD-30W-LT/EP
\t
kw/h
\t
35
\t
Power Input
\t
kw
\t
22.5
\t
Outlet Temp 
\t
degree
\t
-15
\t
Power Supply
\t
\t
380V-3N-50HZ
\t
Refrigerant
\t
\t
R404A
\t
Dimension(L*W*H)
\t
mm
\t
2200*830*1500
\t

Compressor
\t
Type
\t
Scroll
\t
Power(kw)
\t
7.5*3
\t

Condenser
\t
Type
\t
#304 sst Shell and Tubes
\t
Pipe Size(")
\t
1-1/2
\t
Flow(m3/h)
\t
21.31
\t

Evaporator
\t
Type
\t
#304 sst Shell and Tubes
\t
Pipe Size(")
\t
1-1/2
\t
Flow(m3/h)
\t
25
\t


Protector Device
\t
1.Phase protector
2.Overload protector
3.High/low voltage protector
4.Coil overheat protector
5.Anti-freeze protector
Detailed Images

Machine Parts

Name: Compressor 
Brand: Sanyo/ Copeland
Name: Condenser,Evaporator

Brand: Anyda

Name:Control Panel

Brand:Punp

Other Parts

Name: Electrical Parts
Brand: LG/Schneider


Certifications
Packing & Delivery
\t
Packaging
\t
Size
\t
1470 (L) * 800 (W) * 1450 (H)
\t
Weight
\t
550kg
\t



Packaging Details
\t
The normal package is wooden box(Size: L*W*H). If export to european countries,the wooden box will be fumigated.If container is too tigher,we will use pe film for packing or pack it according to customers special request.
FAQ

1.How does a chiller system work?


 
 Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.

2.How to calculate cooling capacity for chillers

   Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86

   Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)


3.Types of chiller system?

   Air Cooled Chiller and Water Cooled Chiller.Water cooled chiller needs a separated cooling tower and has a higher efficiency,but less easier than air cooled.

4.Cooling capacity unit conversion?

1 kcal/h = 1.163W,1 W = 0.8598 kcal/h; 

1 Btu/h = 0.2931W,1 W = 3.412 Btu/h; 

1 USRT = 3.517 kW,1 kW = 0.28434 USRT;  

1 kcal/h = 3.968 Btu/h,1 Btu/h = 0.252 kcal/h; 

1 USRT = 3024 kcal/h,10000 kcal/h = 3.3069 USRT; 


5.The chiller can heat?


    Yes,by the electrical heating wire.Please kindly inform us the hot water temp and heating capacity.

6.Chiller maintenance?

Step 1: Keep Tubes Clean

Step 2: Ensure a Leak-free Unit

Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)

Step 4: Analyze Oil and Refrigerant



Some Customer List
Why Choose Us

1.Reply your inquiry within 12 working hrs.

2.Strong R&D team,more than 15 years of manufacturing chiller experience. OEM&ODM is welcomed.

3.Direct factory,offer customer competitive price with high quality chiller.

4.Strict quality control system,professional QC team.

Contact Us