Share on (60643488754):
Product Description
DOA Rapid Test/one step MDMA test/Ecstacy Rapid Test kits
| Format | Size(mm) | Specimen | Sensitivity |
| Strip | 2.5,3.0 | Urine | 500ng/ml |
| Cassette | 3.0,4.0 | Urine | 500ng/ml |
| Description | Ecstasy pill testing kits are relatively simple, inexpensive products which allows people to test unknown pills to help determine their contents. Because the quality of street ecstasy is notoriously poor, having the ability to at least narrow down the possible contents can help reduce the risks associated with the use of street ecstasy. The ecstasy testing kits contain a combination of chemicals called a 'Marquis Reagant'. A '"reagent" in this case means a chemical or combination of chemicals which, because of the reaction they cause, can be used in the testing or analyses of other chemicals. The primary use of the marquis reagent in the United States is by law enforcement as a field test for the presence of amphetamine and opiates. It's only within the past three years that they have started to be marketed to the public as a harm reduction tool. |
| Urine Tests for Drug Screening | Urine tests are commonly used to test for drugs because they are relatively inexpensive and easy to conduct. They can usually detect the presence of drugs used within seven days before the test being conducted. In the case of a person who has been using a drug like EX, regularly, the results will indicate drug use before the one-week period.
Standard urine tests conducted by a facility may be tested for temperature as well as the presence of drugs. The temperature check is to confirm that the sample was provided by the individual being tested and not switched with someone else's urine in an effort to beat the test.
The urine sample given by the individual being tested is used to detect toxins that remain in the body after illegal drugs are used. The toxins are stored in the fat cells. When the fat is burned in the body, the toxins are released into the bloodstream. Once the toxins reach the bloodstream, they are filtered through the kidneys. Eventually, they are excreted from the body in urine. |
| Sample Collection | Collect urine samples in clean, dry containers, either plastic or glass, without any preservatives. Urine specimens may be refrigerate (2-8 °C ) and stored up to forty-eight hours. For longer storage, freeze samples (-20 °C or below). Bring frozen or refrigerated samples to room temperature before testing.
Urine samples exhibiting visible precipitates should be filtered, centrifuged or allowed to settle. Use only clear aliquots for testing.
|
| Procedure | 1. Review Specimen collection instructions. Test device, patients samples, and controls should be brought to room temperature (20-30) prior to testing. Do not open pouches until ready to perform the assay.
2.Remove the test strip from its protective pouch (bring the device to room temperature before opening the pouch to avoid condensation of moisture on the membrane). Label the device with patient or control number.
3.Fill a test tube or urine cup with sample.Holding the strip vertically,place it into the sample container.the urine level should not be higher than the mix level indicator line on the strip.Do not cover the urine over the max (maximum) line. You may leave the strip in the urine or you may take the strip out after a minimum of 15 seconds in the urine and lay the strip flatly on a non-absorptive clean surface.)and then start the timer. Use a separate pipette and device for each sample or control.
4.Read result between 3 to 8 minutes after the addition of samples. Do not read result after 8 minutes. |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Our service
Packing Details : Standard packing ,neutral packing, your requirement are available
Delivery Details : 7-25 days after receiving the 30% deposit
Shipping Details : DOOR TO DOOR, BY AIR, BY SEA etc.
Payment Details :T/T,Western Union and Paypal are available.
After service:
1.Service tenet: quick and decisive and thoughtful thorough and accurate;
2.Service objectives: service quality to win customer satisfaction;
3.Service efficiency: We will have a dedicated staff to detect problems with the product for testingf if you are not satisfied when you receive your goods, and promptly get back to you within 24 hours.
4.Service principles: products in the course of product issues caused by improper operation, we will provide a solution.
About us




certificates
FAQ
Q1: What's the method u use to do the test?
A: Colloidal Gold Method.
Q2: What's ur MOQ ?
A: Always, for strip format, the MOQ is 1000pcs. While for cassette format, MOQ is 1000pcs, same as midstream.
Q3: What's ur packing of the tests?
A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.
Q4: What's the main differences when comparing products from different suppliers?
A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.
Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.
Q6: How can i distinguish a good test kit?
A: U can judge from the 4facts:
1. Technical data: Such as the accuracy, specificity and sensitivity.
2. Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.
3. Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.
4. Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice.
New products from manufacturers at wholesale prices