SERICO Laboratory AAS Atomic Absorption Spectrophotometer Model AA320N

Share on (60645985050):


Price:

Quantity:


Product Overview

Description


SERICO Laboratory AAS Atomic Absorption Spectrophotometer Model AA320N 


 


20222108 AA320N -1w.jpg  


Item No: 20222108


FEATURES:










































Build-in computer data processing and LCD display



stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.



Stability



Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.



Quickly



The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.



High precision of measurement



Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration



High energy optical path



A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.



Long-life and anti-corrosive atomization system



The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.



Multi-functional analysis mode



for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.



Safe and reliable gas path system



Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.



Complete set of accessories



to be supplied with the instrument and ready for use after they are purchased.



 


Specifications: 


 






































































WL range



190-900nm



WL accuracy



≤±0.5nm



WL repeatability



≤0.3nm (single direction)



Spectrum bandwidth



0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm



Resolution



<40%



Base line stability



±0.004Abs/30min



Characteristic concentration of copper



≤ 0.04μg/ml/1%



Detection limit of copper



≤0.008μg/ml



Background calibration ability



Greater than 30 times



RS232



including



Printer



optional



Power supply



220V 3A, 50Hz



G.W.



160Kg (Main instrument)



 



65Kg ( Accessories )



Package Dimensions



1220x770x730mm (Main instrument)



 



800x400x900mm ( Accessories )



 


 


Standard Accessories:


 


Oil-free air compressor


Glass Atomizer


Cu Hollow cathode lamp


Atomizer unit Burner unit Dust cover


Water-separating gas filter


Titanium burner---10cm


 20222109 AA4530F -2A.jpg


Optional Accessories:


Model GA3202 HGA graphite furnace system


Hydride generator Graphite tubes Software


Recirculating cooling water system


 


 


20222108 AA320N-3.jpg


Shipping Package:


Standard Export Packing


1220x770x730mm (Main instrument)               160Kg


800x400x900mm ( Accessories )                       65Kg


20222108 AA320N -6.jpg


 


 20222108 AA320N -3.jpg.jpg.jpg.jpg



Warranty&Service


WARRANTY 




 


0.21 s.