Share on:
Specifications
item | technical parameters |
|
Max contact power | 10W | 50W |
Max switch voltage | 100VDC/100VAC | 350VDC/300VAC |
Min break down voltage | 150VDC | 600VDC |
Max switch current | DC0.5A | DC0.7A/AC0.5A |
Max carry current | 1.0A | 2.5A |
Max contact resistance | 100mΩ | 100mΩ |
Min insulation resistance | 109Ω | 1010Ω |
Contact life | 107times | |
Operating temperature | -1~+85℃ | |
Applicable environment temperature | -40~+125℃ | |
Min flow rate | ≥1.5L/MIN | |
Max operating flow rate | 15L/MIN,30L/MIN,50L/MIN(optional) | |
Max carry pressure | 1.2 MPa |
PHOTO
Introduction: flow sensor consists of magnetic core, rotating impeller, external casing and sensor. Flow through the sensor activates the magnetic core to trigger switch action, with signal output.
Features: imported components of the magnetic switch, sample working principles, and highly reliable, cheaper price.
Applications: it is used in the control of water circulation, water charging and discharging, water heating, water pump switch on and off of solenoid valve, or powering on and off of water discharging for electric water heater, solar energy water heater, air condition and other water systems.
Fluxostato
Descrição: o interruptor de escoamento do núcleo, e um alojamento do sensor, quando o líquido por condução da operação do núcleo, fazendo com que a operação de comutação, o sinal de comutação de saída.
Características: Importado elemento de comutação magnética, o princípio de funcionamento é simples, confiável e barato.
Aplicações: aquecedor elétrico de água, aquecedores de água solares de controle de circulação de água, condicionadores de ar e outros sistemas de água, fora do controle da água, interruptor de controle da bomba, controle de válvula solenóide on-off ou a força da água, controle da água alimentado.