E7000A SA,Integrated Cable Antenna Spectrum and Power Measurements Analyzer

Share on (60703718529):


Price:

Quantity:


Product Overview

Description


E7000A-SA,Integrated Cable Antenna Spectrum and Power Measurements Analyzer



Contact Us Directly


For quick reply 


For more discounts


For update info : www.weLLzion.com





Product Overview


 


The E7000A-SA RF Analyzer combines the functionality of cable and antenna system analysis, spectrum analysis and power measurements, covering all measurements required for installation, deployment, maintenance and troubleshooting the physical layer of the wireless base station.


Designed specifically for wireless communications field engineers and technicians, the E7000A-SA Series RF Analyzers provide of full range of measurement capability to accurately characterize, maintain and troubleshoot wireless communication sites such as return loss, distance-to-fault
location, tower mounted amplifier gain, antenna-to-antenna isolation, channel power, adjacent channel power, occupied bandwidth and field strength measurements. Interference Analysis function features spectrogram, RSSI, signal identification and location capability.


Standard Measurements & Applications
(Cable & Antenna Analysis)
Fault Location-DFT/RL or DTF/VSWR
Reflection-Return Loss or VSWR
Cable Loss
1-Port Phase
Smith Chart


Standard Measurements & Applications
(Spectrum Analysis)
Spectrum Analysis
Channel Power
Occupied Bandwidth (OBW)
Adjacent Channel Leakage Ratio (ACLR)
Field Strength
AM/FM


Optional Measurement Modes
High Precision Power Meter (DML-015)
Interference Analysis (DML-110)
Coverage Mapping (DML-120)
Transmission Measurement (DML-025)
GPS Receiver (DML-999)





Function & Benefits



  • 6.5 inch TFT LCD display

  • Cable feed line and antenna systems, RF transmission settings and spectrum signal analysis

  • Trace Overlay enables users to easily detect signal and system degradation over time

  • 2065 Data Points enables users to detect faults

  • Multiple Display Modes enables users to set the display to lighting condition

  • Includes over 90 different cable types with the ability to add more

  • Up to 6-Markers can be set for detailed analysis

  • USB HOST,mini USB,LAN





Specifications


Cable Analyzer
Frequency
Frequency Range (E7000A):1MHz~4.4GHz
Resolution:1kHz
Measurement Speed
Reflection :<1.0 mS/point
DTF:<1.25 mS/point
Data Points :130, 259, 517, 1033, 2065
Measurement Accuracy
Corrected Directivity:42 dB (typical, after standard OSL calibration)
38 dB (typical, after eCAL calibration)
Interference Immunity
On-channel:+20 dBm @ >1 MHz of carrier frequency
Off-channel:+13 dBm within ± 10 kHz of carrier frequency
Measurements
Return Loss:0 to 60dB
VSWR:1:1 to 65:1
DTF Range (Distance):1500 meters (4921 feet)
Connectors (Reflection/RF Out)
RF Out:Type N, female, 50Ω
RF Out Damage Level:25dBm, ± 50 VDC


 


Spectrum Analyzer
Frequency
Frequency Range:9kHz~3.0GHz
Tuning Resolution:1Hz
Aging:<± 1.0ppm/yr
Frequency Span:1kHz to 3GHz in 1-2-5 sequence (automode),and 0 Hz (zero span)
Bandwidth
Resolution Bandwidth (RBW):10Hz to 3MHz in 1-3 sequence (auto or manually selectable)
Video Bandwidth (VBW):10Hz to 1MHz in 1-3 sequence (auto or manually selectable)
Spectral Purity (Phase Noise)
@ 1kHz Offset from carrier:-85dBc/Hz
@ 10kHz Offset from carrier:-95dBc/Hz
@ 100kHz Offset from carrier:-100dBc/Hz
Amplitude
Dynamic Range:> 95 dB
Measurement Range:DANL to maximum safe input level
Maximum Safe Input:+30dBm (peak power, input attenuation > 15dB),50VDC
Amplitude Accuracy:≤ ± 1.0 dB
Attenuator Range :0dB to 55dB in 5dB steps
Displayed Average Noise Level (DANL) (Input terminated,RBW=10kHz, Attn=0dBm, Sample Detector)
Preamp Off:≤ -142 dBm, typical (1MHz~1GHz)
≤ -138 dBm, typical (1GHz~3GHz)
Preamp On:≤ -155 dBm, typical (1MHz~1GHz)
≤ -151 dBm, typical (1GHz~3GHz)
Connectors
RF In:Type N, female, 50Ω
RF In Damage:+30dBm, +50VDC
Connectivity
USB host:Type A, 1-Port (connect flash drive for data transfer)
USB client :5-pin mini-B (connect to PC for data transfer)
LAN:10M/100M LAN Port
Data Storage
Internal:1GB, > 2000 saved measurement files
External:Limited by size of USB flash drive
General Specification
Display:6.5 inch TFT LCD (640 x 480)
Battery:Li-Ion, 11.1V, 5.2AH
European EMC:IEC/EN 61326-1:2006
Operating Temperature:-10°C to +55°C
Storage Temperature:-20°C to +75°C
Shock:Mil-PRF-28800F Class 2
Dimension:258mm*173mm*74mm
Weight:2.2 kg