Share on (60712425304):
* Meets EN55022 Class B and CISPR/FCC Class B
* Continuous Short Circuit Protection
* Over Voltage Protection
* Meet EISA 2007/DoE, EU ErP & CoC Version 5
* IEC60320-C14 Inlet, Class I power supply
Typical Model List | ||||||||||||
OUTPUT VOLTAGE | OUTPUT CURRENT | RIPPLE & NOISE (NOTE 2) | VOLTAGE ACCURACY (NOTE 1) | LINE REGULATION (NOTE 3) | LOAD REGULATION (NOTE 4) | MAX OUTPUT POWER | ||||||
9.0-15.0V | 6670mA | 350mV | ±5% | ±1% | ±5% | 80.0W | ||||||
15.1-48.0V | 5960mA | 350mV | ±5% | ±1% | ±5% | 90.0W | ||||||
Specification | ||||
INPUT : | Voltage: | 90~264Vac | ||
Frequency : | 47 to 63Hz | |||
Input Current : | 3.0A max. | |||
Inrush Current : | Cold Start @25℃ 120A max. @240Vac | |||
Leakage Current : | 0.75mA max. | |||
OUTPUT : | Hold-up Time : | 10ms typ. @115Vac | ||
Short Circuit Protection : | Continuous(Auto Recovery) | |||
Over Voltage Protection : | Yes | |||
Temperature Coefficient : | ±0.05%/℃ | |||
GENERAL : | Hi-pot : | Input to output = 1.500VAC | ||
Operating Temperature : | 0 ~ 40℃ | |||
Storage Temperature : | -20 ~ 80℃ | |||
Humidity : | 85% RH max. Non condensing | |||
Cooling : | Natural Convection | |||
Switching Frequency : | 50KHz Typical MTBF ….MIL-HDBK-217F, GB, at 25℃/115VAC….50Khrs min. | |||
Altitude : | 5000m | |||
SAFETY AND EMC : | Emission and lmmunity : | EN55022 Class B, FCC Part 15 Class B EN61000-6-3,EN61000-3-2,EN61000-3-3, EN55024 | ||
Safety : | IEC60950, EN60950, UL60950, IEC60065, EN60065, IEC61558, EN61558 | |||
NOTE: 1. Voltage accuracy at 60% full load. 2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ripple & Noise measurement @20MHz BW. 3. Line regulation is measured from 100V to 240Vac full load. 4. Load regulation is measured from 60% to 100% full load and from 60% to 20% full load (60% +/- 40% full load | ||||