Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6

Share on (60741751606):


Price:$1.95 - $2.20

Quantity:


Product Overview

Description


Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6


Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6


Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROCESS INDICATORS FOR INTERNAL USE (Chemical Process Indicator)

 

 








Single and double strips
MEDIWISH steam sterilization process internal indicators to be used inside the sterilization package. Indicators are designed to demonstrate that the package has been exposed to Steam. They are designed for use in steam autoclaves operating at 121°C/1 bar or 134°C/2 bar.
The indicators change color from yellow to dark brown. By using steam indicators, autoclaved products can be distinguished from non-autoclaved products. These indicators can be delivered from stock. Class 1, according ISO11140-1 standard
Advantages:
• Practical and easy-to-use.
• Easy readout and interpretation due to the high accuracy of the chemical indicator color change.
• Immediate results.
• Low cost.
• Manufactured with Mediwish® inks, 100% Metals Free.
• Laminated option available (MZS-250-L)

Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6


Self-Adhesive labels in sheets,rolls,Indicators tapes and Circle Indicator Label (dot indicators, spot indicators) For External Use










Self-adhesive tapes have been designed to wrap and seal sterilization packages as well as to distinguish between items that have been exposed to Steam sterilization processes from those that have not.


These devices are manufactured in compliance with ISO 11140-1 Standard. Self-adhesive tapes and labels show a color change when exposed to the sterilizing agent.They are commonly placed out of the plate, package or pouch, thereby, products that were processed can be distinguished from unprocessed at a glance. These indicators ensure that the plate, package or pouch has been exposed to a certain process.



Advantages


  It can be adhered to different types of wrap like fabric, paper and plastic.


Manufactured with high quality materials, it offers resistance to physical and chemical damage produced by sterilization processes.


  Easily removable, leaves no residues.


  Allows writing on their surface, facilitating load traceability.


Significant color change allows straightforward differentiation between exposed packages from those unexposed.


Manufactured with Mediwish®  inks, 100% Metals Free.

 Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6


Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6


Self-Adhesive labels for automatic record systems (Load Recordkeeping Labels & Accessories)










Automatic record system labels are printed with Mediwish®  Type 1 indicator ink, 100% metals free.Simple self-adhesive labels and double self-adhesive labels. Double self-adhesive technology allows easy label removal from the sterilization package for data documentation. These indicators are manufactured in compliance with ISO 11140-1 Standard.



Advantages


  Allows traceability of the sterilization process information.


  Eliminates errors in batch number record.


  Easy interpretation of results due to Type 1 indicator accurate change in color.


• Easy removal and re-adherence due to double self-adhesive technology of the Mediwish® automatic record system.


  Quick labeling when using an automatic labelling device.


  Very low-cost.

Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6




































Properties



One-Line Labeller and Labels



Two-Line Labeller and Labels



Three-Line Labeller and Labels


Printer linesOne (Single)TwoThree
Label size:26x12mm26x16mm - 37x19mm29x28mm - 32x28mm
Stylesquare, rectangle, circle or customized as demandsquare, rectangle, circle or customized as demandsquare, rectangle, circle or customized as demand
Sterilization indicatorSTEAM, EO, PLASMA, FORMSTEAM, EO, PLASMA, FORMSTEAM, EO, PLASMA, FORM

STEAM/ETO/FORM indicator tape for medical packaging













































ArticulTape sizePackingCarton sizeWeightSterilization way
101.125012mmx50 meters7627x27x24 cm6.8STEAM, EO, FORM, PLASMA
101.195019mmx50 meters4827x27x24 cm6.8STEAM, EO, FORM, PLASMA
101.205020mmx50 meters4827x27x24 cm6.8STEAM, EO, FORM, PLASMA
101.255025mmx50 meters3627x27x24 cm6.8STEAM, EO, FORM, PLASMA

Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6


Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6


Single and double strips










Mediwish® Type 4 internal control strips as well as
 cards, are multi-variable indicators that rapidly show if critical parameters of the Steam sterilization process have been reached, besides ensuring appropriate Steam penetration of the items inside the packages.
These devices are manufactured in compliance with ISO 11140-1 Standard.



Advantages


  Allows traceability of the sterilization process information.


  Eliminates errors in batch number record.


  Easy interpretation of results due to Type 4 indicator accurate change in color.


  Quick result after sterilization.


  Very low-cost.

Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6


Three-Level Integrators










Mediwish® Three-level Sequential Integrating Indicators designed to react inside loads exposed to Steam sterilization processes. The Integration level consists of a blue ink developed to turn to black when a theoretical population of spores reaches its kill time, indicating that the SAFE condition is achieved.


Level 1 : Exposure level, it turns to black to indicate the exposure to the process but it does not assure that the conditions indicated in the integrator have been met (UNSAFE condition).


Level 2 : Integration level, it turns to black thus indicating that conditions indicated in the integrator have been met. These conditions are calibrated with the kill time of a 106 theoretical Geobacillus stearothermophilus spore population, calculated in a BIER (Biological Indicator Evaluator Resistometer). This is called SAFE condition.


Level 3 : Over-integration level, turns to black when integration conditions indicated in the product have been overreached. This is called EXTENDED condition.

Advantages


Clear instructions and easy to read results.
• Immediate and accurate verifcation of load exposure to correct parameters of sterilization (time, temperature and steam).
• Manufactured with Mediwish® inks,100% Heavy Toxic Metals Free.
• Highly sensitive and accurate.



 


Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6


Emulating Indicators










Emulating Indicators (ISO 11140-1) have been designed for monitoring Steam sterilization processes. They fulfill the requirements for Type 6 indicators monitoring all the critical parameters of the sterilization process at their position in the cham- ber and ensuring an adequate control of the effectiveness of the sterilization processes (temperature, time, steam quality). The wide range of emulators allows the selection of the most suitable indicator for the sterilization process to be controlled, since they are cycle-specific indicators. Mediwish® offers a product of easy interpretation tailored to the requirements of each process.


Mediwish® emulators were developed with Mediwish®  innovative chemical technology,100% metals free, and tested with stringent quality standards.

Advantages


Clear instructions and easy to read results.


Immediate and accurate verification of load exposure to correct parameters of sterilization (time, temperature and steam).


Manufactured with Mediwish®  inks,100% Heavy Toxic Metals Free.


Highly sensitive and accurate.

 


Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6


Bowie & Dick Test Packs










Mediwish® Bowie & Dick Test Pack was developed to control air removal and steam penetration performance in vacuum-assisted steam sterilizers. Mediwish® Bowie & Dick Test Packs are single-use devices that consist of a lead-free chemical indicator, BD Test Sheet, placed between porous sheets of paper, wrapped with crepe paper, with a Steam indicator label on the top of the package. Product BD125X/1 also has a Warning Sheet which contains a circular lead- free chemical indicator, and is placed in the pack at a lower point than the BD test sheet, thus allowing an early detection of air removal failures before they appear on the central chemical indicator. If the circle does not turn to a uniform black color, this is evidence of an imminent failure in the sterilizer, indicating that maintenance should be scheduled.


A uniform and complete color change on the BD Test Sheet indicates adequate air removal and steam penetration. A failure in air removal, poor quality steam, superheated steam and/ or non-condensable gases in steam supply are evidenced as a non-uniform color change in some areas of BD Test Sheet.


Bowie & Dick Test Pack are manufactured under ISO 11140 (Parts 1, 4 and 5) International Standards and elaborated under the Quality Management Systems ISO 13485 and ISO 9001.

Useful tips


  Bowie & Dick Test Pack should be used on a daily basis, every time the sterilizer is put into operation, before the first cycle and the first load to be sterilized. Start a shortened cycle (eg. omitting the phase of post-vacuum drying) to adequately heat up the sterilizer.


Bowie-Dick Test Packs should be used daily; after a sterilizer is installed or relocated; after a sterilizer malfunction; after sterilization process failures; and after major repairs of the sterilizer.


  Place the Bowie & Dick Test Pack horizontally with the chemical label facing up inside an empty chamber, on the bottom shelf or at the front of the sterilizer support and over the drain.

 






































Name:



Autoclave Sterilization indicator BD bowie dick test pack for steam sterilization



Model:



MZS2018



Size:



115x125 mm



Material:



steam penetration (air removal) barriers in the center



Color:



Initial color Yellow change to Brown, blue to brown



Packing:



1pc/bag,50pcs/carton, 28x27x24cm



Features:



Bowie and dick test pack offered by us are single use test packs that allow users to successfully perform daily Bowie & Dick test in an effective & simple way. The advantages of single use test pack is that it is absolute safe in handling & reproducible in results. It consists of a series of steam penetration (air removal) barriers in the center of which is a chemical indicator sheet. Used for daily monitoring of pre-vacuum steam sterilizer. The Bowie Dick pack makes the operator a right control of the autoclave and verify possible defects during Bowie Dick's cycle. Bowie-Dick test packs should be used daily, especially after a sterilizer is installed, relocated, after sterilizer malfunction, after sterilization process failures, and after any major repairs of the sterilizer. Single use Bowie Dick pack is characterized by most reliable test such as:
1. Point out the presence of air leaks in the autoclave immediately and accurately;
2. Nontoxic ink and completely recycled materials;
3. Color Change: yellow to brown
These products are CE marked and meet the requirements of EN 867 and ISO 11140-1; Operation Condition: 134, 3.5 minutes; 120, 15 minutes



Certificate:



CE/ISO 13485



Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6









Test of a tubular load for the test for air removal from the chamber of steam sterilizers "MEDIWISH".
"PCD Helix test MEDIWISH" is a reusable device made of a polymer tube and a plastic container with an internal cavity and includes one-time test strips for each test cycle. Used to control the serviceability of steam sterilizers with forced forvacuum removal in the test cycle: 134 C / 2 min, 121 C / 10 min in an empty sterilization chamber.Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6

Product Features:
    Indicator 2 classes (for special tests) according to ISO 11140-1;     Complies with EN 13060  (Classified as a hollow product of type A) and EN 867-5;
    The result of the test is easily interpreted;
    A sticky layer on the test strip facilitates documentation;
    A clear color transition from the initial yellow to the final dark brown;
    The device is reusable, it is designed for 200 tests;
    Non-toxic, does not contain lead compounds, does not emit harmful and toxic components during application and storage;     The warranty period is 36 months.
Test of "PCD Helix test MEDIWISH" allows timely detection of unsatisfactory removal of air from the sterilization chamber, caused by such reasons as:
    Leakage of the sterilization chamber;
    Failure of the fore-vacuum pump;
    Faulty valves;     Insufficient multiplicity of air evacuation from the chamber.



Disposable Medical Consumables Indicator Integrator Strip Steam 4/5/6









Mediwish Self-Contained Biological Indicators were developed to control Steam sterilization processes. Biological indicators contain bacterial spores inoculated on a carrier packaged within a special plastic tube. Inside the tube, there is a sealed-glass ampoule with a specially-formulated culture medium containing a pH indicator which turns to yellow when spores grow. Mediwish® biological indicators produce visible results within 24 hours and 48 hrs. This products are developed and manufactured under ISO 9001 and ISO 13485 certifed systems. The quality parameters are determined at the time of manufacturing according to ISO 11138 (Parts 1 and 3) standards.


Advantages
• A specially formulated synthetic medium allows to get results in short times. Long-term incubations do not represent an advantage.
• Cross contamination risk reduction.
• Handling and analysis cost reduction.
• Laboratory ovens are not required since culturing may be performed in incubators for biological indicators.
• Type 1 chemical indicator on label.
• Label allows cycle data recording.


 