Waterproof 72v 5000w 1500rpm PMSM high torque brushless dc motor

Share on (60748482724):


Price:

Quantity:


Product Overview

Description



Product Display


_01.jpg


HF-MOTOR_01.jpgHF-motor_02.jpg


























































































































Motor type



Output




Voltage




Load




Speed




Rated Torque




Efficiency




KW




V




A




RPM




N.m




%



BLDC1.55-154


1.55


45


40


4300


3.44


86


BLDC1.8-154


1.8


60


32.6


1100


15.6


92


BLDC1.85-154


1.85


24


81.5


2100


8.41


92


BLDC2.7-154


2.7


60


48.9


1100


23.4


92


BLDC2.8-154


2.8


60


50.8


1100


24.3


92


BLDC2.8B-154


2.8


48


67.8


2600


10.3


86


BLDC3.0-154


3.0


48


67.6


2650


10.81


92.5


BLDC3.0B-154


3.0


72


46.8


1850


15.5


89


BLDC3.5B-154


3.5


60


69.5


1680


19.9


84


BLDC4.0-154


4.0


48


90.6


2580


14.81


92


BLDC5.5-154


5.5


72


85.6


3680


14.27


89.2


 




HF-custom.jpg


 


motor.jpg


 


VIEW MORE PLS CONTACT US >>>


 


 





Other Products


_03.jpg



























Process Flow


_04.jpg 





About Us


_05.jpg_06.jpg 





Packing&Transport


_07.jpg


Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped. 


      What to do: Replace the fuse or reset the breaker.


 


     Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
     What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.


 


     Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
     What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.


 


      Likely cause: Controller may be defective.
      What to do: Verify voltage is coming out of the controller.


 


Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
     What to do: Verify that the motor is wired correctly.


 


     Likely cause: No output power from controller.
     What to do: Measure voltage coming from the controller.


 


     Likely cause: Motor is damaged and the armature is rubbing against the magnets.
     What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.


 


Q:  Motor takes too long to accelerate,what to do?
A:  Likely cause: Motor controller not properly set.
     What to do: Adjust the acceleration trim pot of the controller.


 


     Likely cause: Brushes are worn.
     What to do: Verify brush length.


 


     Likely cause: Bearings may be defective.
     What to do: Inspect bearings. Noisy or rough bearings should be replaced.


 


Q:  Motor runs in the wrong direction,what to do?
A:  Likely cause: Incorrect wiring
     What to do: Interchange the two motor leads.


 


Q:  Motor runs OK but has a clicking noise,what to do?
A:  Likely cause: Suspect a burr on the commutator.
     What to do: Remove burr from commutator using a commutator stone.