Share on (60766751806):

On-Line UPS for IDEAL Choice
9300LRB 10KVA Series
IDEAL-9300LRB 10KVA UPS series is true sine wave double conversion On-line UPS model, design with rack mount or tower convertible cabinet, which provides output power factor 0.9 for high performance and efficiency. Rack mount design cabinet is suitable for protecting high performance rack-mount servers or networking equiptments located within a data center. With Microprocessor control design, it lowers the defective rate of UPS to guarantee high reliability and to protect any critical applications. 9300LRB 10KVA series is available to install isolation transformer inside UPS cabinet for dual voltage output demand or for safety purpose. With battery tray design inside UPS front panel, battery replacement and installation become easy and quick procedures. 4 same capacity UPS are available to connect in parallel max. for capacity expansion. 10kva UPS
* Intelligent Slot (SNMP) and USB management software to monitor UPS status Online UPS
* N+X parallel redundancy for capacity expansion and backup support
* Isolation transformer for dual output voltage system 110/ 220VAC
* ECO mode High efficiency mode for power saving
* Wide input range for extreme voltage instability
* Advanced microprocessor control technology
* External battery bank to extend back-up time
* Emergency power-off EPO function UPS True on line UPS
* True double conversion On Line UPS 10kva UPS
* Automatic self-testing function online UPS
Advanced microprocessor control technology keeps UPS high performance and reliability, operating effectively to save energy.
UPS system works by converting power from AC to DC and then back to AC. Supplying power with zero transfer time to the battery to ensure uninterrupted back-up power when AC power is abnormal, make it ideal for any senstitive devices.
Built-in ECO mode can offer high efficiency when UPS operating. Not only save more money and energy, but reach environmental friendly. 10kva UPS
Supporting Wide Input Voltage range can offers stable power supplying even in bad AC environment. online UPS
Equipped with EPO function can remote UPS power off immediately when any emergency situation happened. Online UPS
Achieve the capacity extension to meet the demand of bigger loading and devices.Provide complete and continueous power protection even if one paralleled UPS is defective. online UPS ups pure sine wave

External battery bank can provide continuous backup power during long-term outage. ups pure sine wave
Dual Output voltage system (110V/ 220V) is accomplishable to satisfy all demand from different electricity system.
Intelligent self-testing function can inspect battery and UPS status to avoid causing any negligence or loss.
Offering well and full range protection such as computer center, accounting center, office and home applications.
UPS installation depends on energy power to support back-up power supply if the mains power fails, using lead-acid batteries with Valve Regulated Lead Acid (VRLA) design, are still the most economical and popular energy source available.
1. Recharge batteries once every 3 months is necessary if it has not be used for a long time.
2. In normal condition, the battery life can last 3-5 years. If the batteries are found in bad condition, earlier replacement should be made.
3. Avoid storage temperatures above 80℉ as battery life is significantly shortened.
Battery period maintenance is needed to prolong the batteries' life and also to resolve impending
problems before they escalate into loss of power to the critical load.
MODEL | IDEAL-9310LRB-12U | |||||
CAPACITY UPS | 10KVA/9KW | |||||
INPUT | ||||||
Phase | 1 Phase 2 Wires + Ground | |||||
Voltage | 208/220/230/240 Vac | |||||
Frequency | 50Hz or 60Hz (Auto Sensing) | |||||
THDi | < 5% with R Full Load | |||||
OUTPUT | ||||||
Phase | 1Phase 2Wires + G or 1Phase 3Wires + G (With Isolation Transformer) | |||||
Voltage | 1Phase 2Wires + G : 208 / 220 / 230 / 240Vac or 1Phase 3Wires + G (With Isolation Transformer) :110 / 220Vac or 115 / 230Vac or 120 / 240Vac | |||||
Voltage Regulation | +/- 1% ( +/- 2% with Isolation Transformer ) | |||||
Frequency (Battery Mode) | 50Hz or 60Hz +/- 0.05Hz | |||||
Waveform | Pure Sinewave | |||||
THD | < 2% (Linear Load) or < 5% (Non-Linear Load) | |||||
Crest Ratio | 3 : 1 | |||||
EFFICIENCY | ||||||
To AC Mode | > 92% at Full Load and Battery Full Charged | |||||
To Battery Mode | > 92% at Full Load and 12VDC / Battery | |||||
ECO Mode | > 96% at Full Load and Battery Full Charged | |||||
BATTERY | ||||||
Voltage | 240VDC | |||||
Type | 12V/9AH *20pcs | |||||
Recharge Time | 8Hrs to 90% | |||||
TRANSFER TIME | ||||||
Line <-> Battery | 0ms | |||||
Inverter <-> Bypass | 0ms | |||||
ECO Mode <-> Inverter | < 10ms | |||||
DISPLAY | ||||||
LED | Normal (Green ) , Bypass (Yellow) , Fault (Red) , Battery (Yellow) | |||||
LCD | Load Level / Battery Voltage / Battery Mode / AC Mode / Bypass Mode Information | |||||
COMMUNICATIONS | ||||||
Interface (Port) | Dry Contact (Optional) ; USB Port | |||||
Intelligent Slot | Slot for SNMP or AS400 card (Optional) | |||||
EPO | Emergency Power Off | |||||
ENVIRONMENT | ||||||
Temperature | 0 - 40℃ (32℉-104℉) | |||||
Humidity | 0-95%, non-condensing | |||||
Acoustic Noise | < 50dB at 1M | |||||
PHYSICAL | ||||||
Dimension(W*H*D) | 440*528*630 MM (12U) | |||||


We, IDEAL, are dedicating on product development and training professional team, we focus on the global market trend to provide innovative power for customers. IDEAL engineering team has professional background experience and technical knowledge and skill, devoting to integrate global market tendency with new technology to ensure products meet the global customer demand. IDEAL design team help customer design customized product package to establish admirable corporate image for marketing.
We are convinced that establishing long-term relationship of mutual trust and mutual benefit between IDEAL and customers is the motion for us to thrive.
With well-trained and professional team, IDEAL support best service and qualified products to customers globally.


1) ODM/OEM experience for more than 20 years.
2) Well-organized manufacturing bases to meet worldwide growing demand.
3) Customized products to meet various applications.
4) Full range of power products
5) High quality products supported by strict quality control system
6) Well-trained workforce and engineer team.
7) Reliable manufacturing supplier on E-commerce online platform

Q1: Why you should install UPS?
When AC Power is off, UPS will offer emergency back-up power to your electronic devices for data loss protection. Power surges are a threat everywhere. UPS can provide fully power protection for over-voltage, under-voltage and surge to offer smooth and consistent flow of power quality to your appliances.
Q2: What electronic appliances should be protected?
All electronic appliances that need long programming times or have to be always accessible would be better to install with a UPS system. This includes computer, medical equipment, data center, server room, networking system and any important electronic appliances.
However, it is not recommended to connect UPS with laser printer or office multi-function fax/printer because they will draw a high initial inrush current at start-up. A typical UPS cannot deal with such a spike.
Q3: What factors can affect UPS battery life time?
Batteries must be kept at ambient temperature of 25°C (77°F). If battery is operated at higher temperatures, its average life will be shortened. The number and length of battery discharges affect a battery's efficiency to deliver power. The more or deeper discharges, the shorter the battery's life will be.
If a battery is undersized for a load, battery run time and life expectancy will also be shortened.
Therefore, it is recommended to replace the batteries every 3 years after initiating the unit.
Recharge batteries every 3 months is necessary if it is not in use.
New products from manufacturers at wholesale prices