Share on (60767316891):

IDEAL 9300LRB 1-20KVA series is true double conversion Online UPS rack or tower convertible type model. With power factor 0.8 / 0.9, it provides high stability and performance when usage. Standard rack mount design can be installed in rack cabinet of data center to offer full range power protection for crucial networking equipment. Smart microprocessor-controlling system assures precious devices under well protection. Individual PDU(Power Distribution Unit) module is designed for 1-3KVA to simplify the steps before UPS maintenance, supporting interruptible power when UPS maintenance. 4sets max. 6-10KVA UPS systems with same capacity or 2 sets max. 20KVA UPS system with same capacity, are available to be connected in parallel for capacity extension. backup UPS systems
* Individual power distribution unit (PDU) for fast and easy maintenance (9300LRB 1-3KVA)
* N+X parallel redundancy for capacity expansion and backup support (9300LRB 6-20KVA) backup UPS systems
* Isolation transformer for dual output voltage system 110/ 220VAC (9300LRB 6-20KVA)
* Intelligent Slot (SNMP) and USB management software to monitor UPS status pure sine wave
* ECO mode High efficiency mode for power saving
* Wide input range for extreme voltage instability battery backup UPS systems
* External battery bank to extend back-up time pure sine wave
* Advanced microprocessor control technology
* True double conversion On Line UPS
* Emergency power-off EPO function battery backup system
* Automatic self-testing function Online UPS

Advanced microprocessor control technology keeps UPS high performance and reliability, operating effectively to save energy. Online UPS
Patent PDU module can save cost and labor hours on UPS maintenance. Online UPS pure sine wave
Supporting Wide Input Voltage range can offers stable power supplying even in bad AC environment. rack mount UPS
Intelligent self-testing function can inspect battery and UPS status to avoid causing any negligence or loss. rack mount UPS
UPS system works by converting power from AC to DC and then back to AC. Supplying power with zero transfer time to the battery to ensure uninterrupted back-up power when AC power is abnormal, make it ideal for any sensitive devices. pure sine wave
Offering well and full range protection such as computer center, accounting center, office and home applications. rack mount UPS
MODEL | IDEAL-9301LRB | IDEAL-9303LRB | ||||
CAPACITY UPS | 1KVA/0.8KW | 3KVA/2.4KW | ||||
INPUT | ||||||
Voltage | 1 Phase 2 Wires + Ground 200/208/220/230/240 Vac | |||||
Voltage Range | 200/208/220/230/240 Vac : 110-300 Vac | |||||
Frequency | 50Hz or 60Hz (Auto Sensing) | |||||
OUTPUT | ||||||
Voltage | 200/208/220/230/240 Vac | |||||
Voltage Regulation | 200/208/220/230/240 Vac : +/- 2% | |||||
Frequency (Battery Mode) | 200/208/220/230/240 Vac : 50Hz or 60Hz +/- 0.2Hz | |||||
Waveform | Pure Sinewave | |||||
THD | 200/208/220/230/240 Vac : < 3% (Linear Load), < 5% (Non-linear Load) | |||||
Crest Ratio | 3:1 | |||||
EFFICIENCY | ||||||
To AC Mode | 200/208/220/230/240 Vac : > 88% at Full Load and Battery Full Charged | |||||
To Battery Mode | 200/208/220/230/240 Vac : > 85% at Full Load and Battery Full Charged | |||||
ECO Mode | 200/208/220/230/240 Vac : > 93% at Full Load and Battery Full Charged | |||||
BATTERY | ||||||
Voltage | 36VDC | 96VDC | ||||
Type | 12V/7AH*3pcs | 12V/7AH*8pcs | ||||
Recharge Time | 5Hrs to 90% | |||||
TRANSFER TIME | ||||||
Line <-> Battery | 0ms | |||||
Inverter <-> Bypass | <4ms | |||||
ECO Mode <-> Inverter | < 10ms | |||||
DISPLAY | ||||||
LCD Display | Input, Output, Load, Battery, Mode/Fault/Warning code, Inverter operating, Bypass operating, Output voltage and frequency and Bypass disable / enable selection information | |||||
PHYSICAL | ||||||
Dimension | 480*440*88mm | (480*440*88mm)*2 | ||||
MODEL | 9306LRB-12U | 9310LRB-12U | IDEAL-9320LRB-19U | |||
CAPACITY UPS | 6KVA / 5.4KW | 10KVA/9KW | 20KVA / 18KW | |||
INPUT | ||||||
Phase | 1 Phase 2 Wires + Ground | |||||
Voltage | 208/220/230/240 Vac | |||||
Frequency | 50Hz or 60Hz (Auto Sensing) | |||||
OUTPUT | ||||||
Phase | 1Phase 2Wires + G or 1Phase 3Wires + G (With Isolation Transformer) | |||||
Voltage | 1Phase 2Wires + G : 208 / 220 / 230 / 240Vac or 1Phase 3Wires + G (With Isolation Transformer) :110 / 220Vac or 115 / 230Vac or 120 / 240Vac | |||||
Voltage Regulation | +/- 1% ( +/- 2% with Isolation Transformer ) | |||||
Frequency (Battery Mode) | 50Hz or 60Hz +/- 0.05Hz | |||||
Waveform | Pure Sinewave | |||||
THD | < 2% (Linear Load) or < 5% (Non-Linear Load) | |||||
Crest Ratio | 3 : 1 | |||||
EFFICIENCY | ||||||
To AC Mode | > 92% at Full Load and Battery Full Charged | |||||
To Battery Mode | > 92% at Full Load and 12VDC / Battery | |||||
ECO Mode | > 96% at Full Load and Battery Full Charged | |||||
BATTERY | ||||||
Voltage | 240VDC | |||||
Type | 12V/7AH *20pcs | 12V/9AH *20pcs | 12V/9AH *20pcs * 2sets | |||
Recharge Time | 7Hrs to 90% | 8Hrs to 90% | 8Hrs to 90% | |||
TRANSFER TIME | ||||||
Line <-> Battery | 0ms | |||||
Inverter <-> Bypass | 0ms | |||||
ECO Mode <-> Inverter | < 10ms | |||||
DISPLAY | ||||||
LED | Normal (Green ) , Bypass (Yellow) , Fault (Red) , Battery (Yellow) | |||||
LCD | Load Level / Battery Voltage / Battery Mode / AC Mode / Bypass Mode Information | |||||
PHYSICAL | ||||||
Dimension(W*H*D) | 440*528*630 MM (12U) | 440*528*836 MM | ||||



We, IDEAL, are dedicating on product development and training professional team, we focus on the global market trend to provide innovative power for customers. IDEAL engineering team has professional background experience and technical knowledge and skill, devoting to integrate global market tendency with new technology to ensure products meet the global customer demand. IDEAL design team help customer design customized product package to establish admirable corporate image for marketing.
We are convinced that establishing long-term relationship of mutual trust and mutual benefit between IDEAL and customers is the motion for us to thrive.
With well-trained and professional team, IDEAL support best service and qualified products to customers globally.


1) ODM/OEM experience for more than 20 years.
2) Well-organized manufacturing bases to meet worldwide growing demand.
3) Customized products to meet various applications.
4) Full range of power products
5) High quality products supported by strict quality control system
6) Well-trained workforce and engineer team.
7) Reliable manufacturing supplier on E-commerce online platform

Q1: Why you should install UPS?
When AC Power is off, UPS will offer emergency back-up power to your electronic devices for data loss protection. Power surges are a threat everywhere. UPS can provide fully power protection for over-voltage, under-voltage and surge to offer smooth and consistent flow of power quality to your appliances.
Q2: What electronic appliances should be protected?
All electronic appliances that need long programming times or have to be always accessible would be better to install with a UPS system. This includes computer, medical equipment, data center, server room, networking system and any important electronic appliances.
However, it is not recommended to connect UPS with laser printer or office multifunction fax/printer because they will draw a high initial inrush current at start-up. A typical UPS cannot deal with such a spike.
Q3: What factors can affect UPS battery life time?
Batteries must be kept at ambient temperature of 25°C (77°F). If battery is operated at higher temperatures, its average life will be shortened. The number and length of battery discharges affect a battery's efficiency to deliver power. The more or deeper discharges, the shorter the battery's life will be.
If a battery is undersized for a load, battery run time and life expectancy will also be shortened.
Therefore, it is recommended to replace the batteries every 3 years after initiating the unit.
Recharge batteries every 3 months is necessary if it is not in use.
New products from manufacturers at wholesale prices