Share on (60784086424):
⑴Product Name: frost proof yard hydrant
⑵Material: cast iron
⑶Color: red, blue, green, black, yellow, white(or as you like)
⑷Links: steel-zinc plated
⑸Connector: Brass
⑹Outlet joint: Brass
⑺Hose adapter: Brass
⑻Valve : Brass
⑼Pipe: Steel-galvanized
⑽Brand: ALAN(or as you like)
⑾Package: inter package white carton or others outer package in iron stand
⑿Use: -30-80 centigrade degree, applicable in the outdoor or cold conditions, The pressure can not more than 80 Psi non-corrosive water or devices, with environmental protection, energy saving, easy to use and so on
Model | Bury Depth | Overall Length | Export conjunction size | Entrance conjunction size | Drainage outlet conjunction size |
ALAN-YH301 | 1" | 39 | 3/4-11.5NH | 3/4-14NPT | 1/8-27NPT |
ALAN-YH302 | 2" | 51 | 3/4-11.5NH | 3/4-14NPT | 1/8-27NPT |
ALAN-YH303 | 3" | 63 | 3/4-11.5NH | 3/4-14NPT | 1/8-27NPT |
ALAN-YH304 | 4" | 75 | 3/4-11.5NH | 3/4-14NPT | 1/8-27NPT |
ALAN-YH305 | 5" | 87 | 3/4-11.5NH | 3/4-14NPT | 1/8-27NPT |
ALAN-YH306 | 6" | 99 | 3/4-11.5NH | 3/4-14NPT | 1/8-27NPT |
ALAN-YH308 | 8" | 123 | 3/4-11.5NH | 3/4-14NPT | 1/8-27NPT |
ALAN-YH310 | 10" | 147 | 3/4-11.5NH | 3/4-14NPT | 1/8-27NPT |



We have long argued that the delivery is the start of our cooperation, to provide high quality service is our consistent pursuit, established a quick service for the customer channel, the company sets product service center, have a professional service team, including senior professional engineers and professional technicians. Set up after-sales service hotline and complaint hotline to ensure customer's request and timely solution of problems in product use. As long as you call our service hotline or the telephone of the sales service network, whether pre-sale, sale, or after-sales service will be effectively solved.
The hydrant is closed and no water is in the riser pipe or head. Water is stopped by the plunger (valve) below the frost line. Protected like this, no freezing can occur.
Water is made available by raising the handle. This will lift the plunger allowing water to flow and the plunger to seal off the drain hole.
NOTE: WATER FLOW CANNOT BE THROTTLED.
Hydrant handle must be positioned in the FULL open position for proper water flow and drainback seal. This hydrant will not operate properly in a PARTIALLY open position.
Closingthe handle pushes the plunger down to seal off the water and uncover the drain hole. This allowsthe water in the head and riser pipe to drain back down into the gravel drain bed. The hydrant is now empty and cannot freeze.

1. Dig hole for hydrant approximately 2 feet in diameter and 1 foot deeper than the bury depth.
2. FLUSH PIPING BEFORE CONNECTING THE HYDRANT to clear any gravel or other debris that may have collected in the piping during its installation and assembly. If not flushed out of the piping, this debris may jam the hydrant mechanism or clog the flow ports.
3. Make the piping connection* but do not bury the hydrant yet. Operate the hydrant to be sure it is operating properly and the piping connections are not leaking. Open and close the hydrant and check for flow and drainage. If leakage continues from the drain port see “adjustment procedure” below.
4. Fill the hole around and below the hydrant with medium size gravel. This will provide a drain field for the hydrant. Without a drain field. the hydrant will not empty itself and it will freeze in cold weather. This will cause damage to the hydrant and result in loss of water and possible flooding damage.
* CAUTION: USE WRENCH ON VALVE BODY & FIlliNG ONLY. Do NOT use wrench on stand pipe.
·Never leave hose attached to hydrant after use.This will prevent the hydrant form draining properly and will allow the hydrant to freeze.
·If the hydrant is to be installed inside a barn or other structure,or if it is installed in asphalt or concrete such as a driverway,connect a 1/8” drain pepe or tube to the drain port and dig a remote drain filed out-side the structure for the drain pipe to empty into.Without this remote piping and drain filed,the water from the hydrant drainage will percolate up to the surface around or near the hydrant and will damage the flooring or cause muddy areas in stalls or walkways.
·Water pressure to the hydrant should be regulated tonot more than 80 psi.The higher pressures will accelerate wear and may cause leakage that will saturate the ground and drain field and prevent the hydrant from draining. If the hydrant is not allowed to drain, it can freeze and cause damage to itsekf and cause flooding and loss of water. High pressure will also cause you to have to replace parts and adjust the hydrabt frequently.A normal operating pressure would be 20 to 40 psi.
·Saturated ground in the hydrant drain filed can prevent the hydrant from draining and may result in freezing.If the area where your hydrant is located is low laying or has a tendency to have standing water,a larger drain field or pit may be required to provide the hydrant a place to drain into.
we keep offering our customers high quality products.


Packing Details : Packing, solid bicycle saddle, 50pcs/carton
Delivery Details : 3-30 days after order of Solid bicycle tire tubes

We have long argued that the delivery is the start of our cooperation, to provide high quality service is our consistent pursuit, established a quick service for the customer channel, the company sets product service center, have a professional service team, including senior professional engineers and professional technicians. Set up after-sales service hotline and complaint hotline to ensure customer's request and timely solution of problems in product use. As long as you call our service hotline or the telephone of the sales service network, whether pre-sale, sale, or after-sales service will be effectively solved.

Create value for customers, win rewards for shareholders, create dreams for employees!
Provide the world with high quality, durable hydrant, pay more efforts!
Become China's Frost Proof Yard Hydrant leading industry leader.
A: We are factory.
A: Generally it is 5-10 days if the goods are in stock. or it is 30days if the goods are not in stock, it is according to quantity.
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
A: 30% T/T in advance ,balance before shippment.
If you have another question, pls feel free to contact us as below: