Reverse Osmosis Quick Replacement 100 Gdp Membrane For Home Ro Plant Filter Water Treatment Plant Water Filter System Price

Share on (60794405656):


Price:$9.72 - $13.98

Quantity:


Product Overview

Description


100gdp RO Membrane


75g1.jpg


Reverse osmosis (RO) is a water purification technology that uses a semipermeable membrane to remove ions, molecules, and larger particles from drinking water.


Our Company manufacturer all series reverse osmosis element ,and especially commercial field ,got very good feedback from our customers .


Uses the most advanced membrane film technology and manufacturing processes


Provides high rejection stability even with high TDS manufactured in our ISO 9001:2008 Certified Facilities,


Less fouling, Less frequency cleaning and More consistent


100% Performance and Quality Tested


Backed by our Experienced Technical Support Staff


High Quality for Consistent and Reliable Performance


Standard dimensions to fit in commonly available housings


Lower consumption of chemical and longer life


 

































































































Model



1812-75



2012-100



3012-200



3012-300



3013-400



 



Effective membrane area ft²(m²)



ft²



5



6



10



14



16





0.46



0.56



0.92



1.3



1.48



Performance



Salt Rejection



%



98%



98%



98%



98%



98%



Permeate



GPD



75



100



200



300



400



m3/d



0.28



0.38



0.76



1.14



1.51



Test Condition



Test Liquid concentration(as Nacl)mg/L


(ppm)



250



Test Liquid Pressure psi(Mpa)



65(0.45)



Test Liquid Temperature(℃)



25



Recovery rate(%)



15



Service Conditions



Max.water temperature



45



Continuous running water PH range



3~10



Chemical cleaning water PH range



2~11



Max.inflow SDI



5



Free chlorine concentration(mg/L)



<0.1



Notice: Permeate flow for individual elements may vary ±15 percent.


The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:


1.  450PPM NaCl solution,tap water


2. Applied Pressure: psi(Mpa) refer to the form


3. 77°F (25°C) Operating Temperature


4. 30% Permeate Recovery


5. 7.0~8.0 pH Range


 


Standard Operating Limits:


Maximum Operating Temperature: 113ºF (45ºC)


Maximum Applied Pressure: 300psi(21bar)


pH Range, Continuous (Cleaning): 3-10


Maximum Feedwater SDI (15 mins): 4


Maximum Chlorine Concentration: < 0.1 PPM


 


limiting condition for operation (LCO)


Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, GALLON recommends removing residual free chlorine by pretreatment prior to membrane exposure. Please refer to GALLON technical bulletin for more information.


When pH Range> 10,maximum Operating Temperature less 95℉(35℃)


 















  • Restaurants

  • Aquariums

  • Whole House 

  • Office

  • Institutions

  • Hotels

  • Hospitals

  • Spot Free Rinse/Car Wash

  • Labs

  • Pharmaceutical





  • Humidification

  • Misting

  • Manufacturing

  • Rinse Water

  • Bottled Water

  • Beverage

  • Food Processing

  • Ice Makers

  • Commercial Water Purifier

  • Wide Variety of Other Applications














 


6.jpg7.jpg9.jpg10.png11.png12.png.jpg


 


13.png


5.jpg1.jpg2.jpg


0.2714 s.