Real time household environment control Decentralized Heat Recovery System Units

Share on (62002887201):


Price:$2,004.00 - $2,506.00

Quantity:


Product Overview

Description


heat recovery system

Heat Recovery System Filtered Exhaust Fan Decentralized Ventilation Units

Product Description

 

Based on the traditional air exchanger, Benclimate Fresh Air Heat Pump adds airconditioning heat pump system. It overcomes the weaknesses of high energy consumption and big temperature fluctuation of traditional fresh air exchanger. It controls the fresh air at a constant temperature and humidity, and the regulation of indoor CO2, harmful gases, concentration of fine particulate matter (PM2.5). So it makes the transport of fresh air into the room more comfortable and healthy.

heat recovery system

 

Compared to the traditional fresh air exchanger, below are our advantages:

1.The two-stage heat recovery system with heat pump and air heat exchanger.

2.Balanced ventilation deals with indoor air fast and efficiently to improve its quality.

3.Full EC/DC motor.

4.Special PM2.5 filter with high efficiency and low resistance.

5.Real-time household environment control.

6.Smart learning function and APP remote control.

 heat recovery system

 

 

Working principle of  Heat Pump Type Heat Recovery Ventilator

 

It can expel the stale air indoor out of room, meanwhile supplying the fresh air outside into the room, by using the advanced heat/energy recovering technology, the energy can exchange taking advantage of the difference of the temperature and humidity between indoor and outdoor air. By this means, it can not only smooth away the problem of indoor pollution, but also saving energy.

 heat recovery system

 

Filters:

heat recovery system

 

 

Energy saving principle of  Heat Pump Type Heat Recovery Ventilator

heat recovery system

 

Secification of  Heat Pump Type Heat Recovery Ventilator

 

heat recovery system

 

Controller description

heat recovery system

1. The airflow is controlled according to the ambient temperature.

2. Compressor and bypass control

3. The central controller can manage, monitor and control the whole system.
4. Functions of central controller

(1) Timely display of operation data
(2) Timely display of operation status of individual part
(3) Specific check to any data of ay unit
(4) Airflow adjustment according to ambient temperature
(5) Auto defrosting (6) Auto bypass
(7) Heat pump
(8) Auto restart
(9) Filter monitor G4: 3 months cleaning reminder
F7: 6 months cleaning reminder
H10: 12 months cleaning reminder

(10) Auto water drain
(11) Alarm
A. Fault alarm of refrigerantion system, high pressure or low pressure alarm
B. Communication failure alarm
C. Frosting alarm
D. Short connection or wrong connect of the sensors
E. Sensors lack or faults alarm
F. Over heating of electrical heater
G. Time resetting after euqipment faults
H. Fire alarm (if return air temperature higher than 45°C.)

heat recovery system

 

Specification of HPERV-150 heat pump heat recovery ventilator

Model HPERV-150
Installation type Suspended type
Cooling cap.W750
Heating cap.W880
Cooling powerW260
Cooling currentA1.23
Heating powerW260
Heating currentA1.23
Max.service ratingW400
Max.running currentA1.9
Compressor/Constant speed compressor
PowerV/Ph/Hz220-240/1/50
Airflowsm3/h70~150
E.S.PPa80
NoisedB(A)31
Dimensionmm100
Condensate drain dimensioninch(BSP)1/2"
Motor dimension(L/W/H)mm840/685/250
Package dimension(L/W/H)mm891/731/358
Net weight/Gross weightKg43/50
Refrigerant R134a
Company Information

Holtop Factory

Holtop is the leading manufacturer in China specializing in the production of air to air heat recovery equipments. It is dedicated to the research and technology development in the field of heat recovery ventilation and energy saving air handling equipments since 2002. The main products includes energy recovery ventilator ERV/HRV, air heat exchanger, air handling unit AHU, air purification system. Besides, Holtop professional project solution team can also offer customized hvac solutions for different industry. 

Holtop headquarters is located at the foot of Beijing Baiwangshan Mountain, covering area of 30,000 square meters. The manufacturing base is in Beijing's Badaling Economic Development Zone, covering an area of 60 acres, with an annual production capacity of 200,000 units of air heat recovery equipments.
Holtop builds a sound certificate system of ISO9001, ISO14001 and OHSAS18001 as well as product certification systems. Moreover, it has a laboratory certified by national authority. As a well-known manufacturer in the field of heat recovery, Holtop has a strong R&D team and possesses dozens of national invention patents, and participated in the compilation work of several national standards, Holtop was also elected as Zhongguancun High-Tech Enterprise.

heat recovery system

 

Holtop partner

Holtop cooperate with world famous brand or offer OEM service.

heat recovery system

Holtop products stand for TOP quality in heat recovery ventilation filed in China, certificated by CE, CB, RCM, RoHs, FCC, ISO and other different approved tests like anti-flaming test, anti-mold test, energy saving product test. etc.
heat recovery system

 


0.1888 s.