One-key operation, automatic operation, isothermal Oxidative induction time special equipment
Conforming the following standards: GB/T 19466.6- 2009/ISO 11357-6:1999
Support one experiment to measure 2 samples
Features:
\tNew sensor sample support, fully closed structure design, prevent items from falling into the furnace body.
\tSupport to measure two samples at the same time, the efficiency is greatly improved by 2 times. It is very convenient to measure multiple samples at the same furnace body at the same time. If we make 5 sample data in strict accordance with the requirements of national standard, we can finish the data quantity measured in 1 day instead of 2 days. It can not only save time, but also ensure the uniformity of data measurement conditions and quickly judge the sample uniformity.
\tBuilt-in 10.8-inch computer, no additional computer, integrated equipment; The display is rich in information, including setting temperature, sample temperature, oxygen flow rate, nitrogen flow rate, differential heat signal, various switching states, etc.
\tThe right side of the instrument is equipped with standard four USB interfaces, which are convenient for users to connect external devices such as mouse, keyboard, printer and USB flash drive, and convenient for users to use.
\tPre-installed software, reduce computer adaptability problems, reduce due to the replacement of the use of the computer, installation drive error caused by the connection problems.
\tWindows 10 system is equipped with 32GB capacity and 2GB system memory. Data can be stored inside the instrument without u-disk transfer. The touch screen and mouse button can be used for operation
\tThe furnace structure is compact, and the rate of rising and cooling is adjustable.
\tThe installation process is improved, and the mechanical fixation method is adopted to completely avoid the contamination of the internal colloidal of the furnace to the differential heat signal.
\tThe furnace is heated by heating wire, compact structure and small size.
\tThe double temperature probe ensures the high repeatability of the sample temperature measurement, and adopts the special temperature control technology to control the temperature of the furnace wall to set the temperature of the sample.
\tThe gas flow meter automatically switches between two channels of gas, with fast switching speed and short stable time.
\tStandard sample is provided for easy adjustment of temperature coefficient.
\tSoftware support each resolution screen, automatically adjust the computer screen size curve display mode. Support laptop, desktop; Support Win2000, XP, VISTA, WIN7, WIN8, WIN10 and other operating systems.
\tSupport user edit device operation mode according to actual needs to achieve full automation of measurement steps. The software provides dozens of instructions, and users can flexibly combine and save each instruction according to their own measurement steps. Complex operations are reduced to one-click operations.
Parameters:
1.\tTemperature range: RT-500℃
2.\tTemperature resolution:0.01℃
3.\tHeating rate: 0.1~80℃/min
4.\tCooling rate: 0.1~30℃/min
5.\tConstant temperature: RT-500℃
6.\tDuration of constant temperature: The duration is recommended to be less than 24 hours.
7.\tQuantity of samples for a single test: 2 samples at a time
8.\tTemperature control mode: Constant temperature rise, constant temperature
9.\tDSC range: 0~±500mW
10.\tDSC resolution: 0.01mW
11.\tDSC sensitivity: 0.01mW
12.\tWorking power: AC 220V 50Hz 300W or other
13.\tAtmosphere control gas: Two-channel gas control by automatic controlled (e.g. nitrogen and oxygen)
14.\tGas flow:0-200mL/min
15.\tGas pressure:0.2MPa
16.\tGas flow accuracy: 0.2mL/min
17.\tCrucible: Aluminium crucible Φ6.6*3mm (Diameter * High)
18.\tCalibration standard: with standard material (indium, tin, zinc), users can adjust the temperature by themselves
19.\tData interface: Standard USB interface
20.\tDisplay mode: 10.8-inch touch computer
21.\tOutput mode: computer and printer
22.\tFully closed support structure design, prevent items falling into the furnace body, pollution of the furnace body, reduce the maintenance rate