HT-208
feature
--Pocket-size clamp meter
--6000 counts
--Sample Rate is 2 times/sec
--AC current measuring capability up to 1000Amps
--True RMS measurement on AC mode
--Inrush Current Measurement
--NCV (Non-Contacted Voltage detection)
--Data hold
--Auto Power Off (15 min)
--Backlight
--Auto Ranging
--Low Power Indication
--EN61010 600V CAT III
specifications | range | accuracy | ||
HT208A | HT208B | HT208D | ||
DC Voltage | 6V/60V/600V/1000V | ±(1.0%+3) | ±(1.0%+3) | ±(1.0%+3) |
AC Voltage | 6V/60V/600V/750V | ±(1.2%+3) | ±(1.2%+3) | ±(1.2%+3) |
DC Current | 60A/600A/1000A |
|
| ±(3.0%+5) |
AC Current | 60A/600A/1000A | ±(3.0%+5) | ±(3.0%+5) | ±(3.0%+5) |
Resistance | 600Ω/6KΩ/60KΩ/600KΩ/6MΩ/60MΩ | ±(1.0%+3) | ±(1.0%+3) | ±(1.0%+3) |
Capacitance | 60nF/600nF/6uF/60uF/600uF/6mF/60mF | ±(4.0%+3) | ±(4.0%+3) | ±(4.0%+3) |
| 100mF | ±(5.0%+5) | ±(5.0%+5) | ±(5.0%+5) |
Frequency | 10Hz/100Hz/1kHz/10kHz/ 100kHz/1MHz/10MHz | ±(1.0%+3) | ±(1.0%+3) | ±(1.0%+3) ±(1.0%+2) |
Duty | 1%~99% | ±(1.0%+2) | ±(1.0%+2) | ±(1.0%+3) |
Temperature(℃/°F) | -40℃~1000℃ | ±(1.0%+3) | ±(1.0%+3) | ±(1.0%+3) |
-40°F~1832°F | ±(1.0%+3) | ±(1.0%+3) |
| |
Counters | 6000 | 6000 | 6000 | |
Auto/manual range | √ | √ | √ | |
Bargraph |
| √ | √ | |
NCV (LED and Buzz) | √ | √ | √ | |
Diode | √ | √ | √ | |
Continuity (LED and Buzz) | √ | √ | √ | |
MAX/MIN hold | √ | √ | √ | |
Data hold | √ | √ | √ | |
True RMS | √ | √ | √ | |
AC bandwidth | 1KHZ | 1KHZ | 1KHZ | |
Low battery indication | √ | √ | √ | |
Auto power off | √ | √ | √ | |
Double color backlight | √ | √ | √ | |
Flashlight | √ | √ | √ | |
LPF |
| √ | √ | |
V-Loz |
| √ | √ | |
Power:2*AA batteries
Weight:Appro*.380g
Size:240mm*85mm*40mm
Safety rating:EN61010-1,-2-030
EN61010-2-033
EN61326-1