Busic functions | ||
Start frequency | 0.00Hz~600.00Hz | |
Accel/Decel time | 0.00s~60000s | |
Carrier frequency | 0.5KHz-16КHz | |
Frequency command modes | Digital setting+Keyboard Up/Down;Digital setting + terminal Up/Down. Communication setting.Analog setting:AI1/AI2/AI3. Terminal pulse setting. | |
Start methods | Start from starting frequency. DC injection braking at start:Flying start. | |
Stop methods | Ramp to stop. Coast to stop. DC injection braking at ramp stop. | |
Dynamic brake capability | Braking unit triggered voltage:650-750V. Service time:0.0s~100.0s. Brake units of G600-4T75 and below are optionally inbuilt. | |
DC braking capability | DC braking start frequency: 0.00Hz~600.00Hz. DC braking current: constart torque 0.0%~100.0%. DC braking time:0.0s-100s. | |
Input terminals | Seven digital input terminals, one of them can be used for pulse input. Support dry contact active PNP and NPN input. Three analog input terminals, one of them is voltage only and the other two are voltage/current programmable | |
Output terminals | One high-speed pulse output (0kHz~50kHz square wave output) and two analog outputs (voltage/current programmable), can output signals such as command frequency,output frequency etc.One digital output. One delay outputs. | |
Encode input terminals | One high-speed pulse output (0kHz~50kHz square wave output) and two analog outputs (voltage/current programmable), can output signals such as command frequency,output frequency etc.One digital output. One delay outputs. | |