Share on:
Single-Scale HMI Ration Batching Weighing Controller for Concrete Batching Machine Four Bins Aggregate Batcher hopper
Main Features:
² Suitable for Ration Batching Scale with 14-Material&2-Speed Feeding or 16-Material&1-Speed Feeding [Single-scale Mode].
² EMC design with high anti-jamming capability, suitable for industrial environment.
² Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash.
² 7”/10.2” Ultralight and ultrathin TFT touch screen with embedded weighing/control module.
² Loadcell Interface
l Max. Connection Quantity: 16 Loadcells (350Ω).
l 24-bit High-precision and high-speed ∑-A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 800Hz.
l Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.
² I/O Interface
l 9 Definable normally open switch inputs [DI] and 18 definable normally open transistor switch outputs [DO].
l Optional ‘High/Low Speed Feed’ DOs for feeding control. Optional Low-speed Feeding Modes: Continuous Feeding Mode and Inching Feeding Mode.
l 2 Definable analog signal AO[0~10V] for weight signal output or ‘High/Low Speed Feed’ control.
² Digital Communication Interface
l COM1[RS232]&COM2[RS485] for connecting Host IPC/PLC and LED Remote Display.
l COM[RS232] for connecting RS232 Serial Printer.
l USB1 for connecting USB mouse, downloading HMI software from U-disk and copying data to U-disk.
² Software Function
l Manual Screen-locking/Screen-unlocking, Auto Screen-locking, Digital Setting&Calibration and I/O Testing functions available.
l Initial Zero Adjustment after Power-on, Auto Zero Tracking, Zero Fine Adjustment and Zero Calibration functions available.
l Load Calibration and Loss Calibration functions available.
l 10 Recipes for batching control.
l Optional ‘Fall Value Auto Correction’ function.
l Optional ‘Auto Pause for Deviation Alarm’, ‘Auto Pause while Gross Weight Upper Limit Alarming’, ‘Manual Pause’ and ‘Auto Re-feed’ functions.
l Optional ‘Target Batch Control’ function [With Target Batch Count finished, the batching process will stop automatically].
l The Batch Records can be printed automatically.
l Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
l With the multitasking mode, the weighing&control process will not be interrupted by parameter setting and the other operations.
Name | Operation | Note |
[Login] | User Login. Exfactory Passwords: ² Operator: None. ² Engineer: 0. ² Administrator: 1. | Operation ‘Main Menu / F5 User / Password / PSW Set’ for Modifying Password. |
[User Name] | After password inputted, the matching User Name will be displayed. | ² Operator: User with lowest authorization. ² Engineer: User with higher authorization. ² Administrator: User with highest authorization. |
[Operate] | Enter ‘Main Operation Interface’. | Operation ‘Main Menu / F5 User / Password / Login [Logoff]’ for Re-login and Logoff. |