K2 One Step Test Device ,CE&FSC&ISO approved .Rapid and easy to get the results.

The K2 Synthetic Cannabinoid Rapid Test Cassette is a lateral flow chromatographic immunoassay for the qualitative detection of K2 Synthetic Cannabinoid in urine at the cut-off concentration of 50ng/ml.

Parameter table

 

Model NumberN-K2
NameK2 Synthetic Cannabis Drug Urine Rapid Test Cassette(Urine)
Product TypePathological Analysis Equipments
SpecimenUrine
FeaturesHigh sensitivity, simple & easy to use and the result is accurate .
FormatsStrip, cassette
Size3mm,4mm or according your request
Sensitivity50/200ng/ml
StorageAt Room Temperature
ShippingBy sea/By air/TNT/Fedx/DHL

 

Test  Procedure:
1.Remove the Urine K2 Synthetic marijuana Drug Test Kit from the sealed pouch and used it as soon as possible.
2. Remove the cap from the end of the test card. With arrows pointing toward the urine specimen,immerse the strip(s) of the test card vertically in the urine specimen for at least 10-15 seconds.
3. Wait for colored lines to appear. Interpret the test results at 3-5 minutes.

How To Use ?

For Strip 

1.When you are ready to begin testing, open the sealed pouch by tearing along the notch. Remove the test from the pouch.                                    

2. Immerse the strip into the container with the arrow end pointing towards the container. Do not immerse past the MAX (maximum) line. Take the strip out after 8-10 seconds and lay the strip flat on a clean, dry, nonabsorbent surface       

3.Wait 3-8 minutes and read result. Do not read results after 8 minutes.11.png

For Cassette

1.Review “Specimen collection” instructions. Test device, patient’s samples, and controls should be brought to room temperature (20-30℃) prior to testing. Do not open pouches until ready to perform the assay.

2.Remove the test device from its protective pouch (bring the device to room temperature before opening the pouch to avoid condensation of moisture on the membrane). Label the device with patient or control number.

3.Hold the dropper vertically and transfer 3 full drops of urine (approx. 0.15ml) to the specimen well (S) of the test device, and then start the timer. Use a separate pipette and device for each sample or control.

4.Read result between 3 to 8 minutes after the addition of samples. Do not read result after 8 minutes.22.png

How To Read ?

 

Positive: Only one pink band appears on test region of the Cassette.

 

Negative: Two pink bands appear on test region of the Cassette.

 

Invalid: If without colored band appears on test region, this is an indication of a possible error in performing the test. The test should be repeated using a new device.