Description

Our CELLCHECK intelligent battery monitor is designed special for single cell monitoring. It combines advanced technology with patented hardware for the most thorough stationary battery health analysis in the industry. The module can be pasted on the monitored battery's case directly or mounted an additional rail.

Product Name
H3G-TV1.2V192S1CT Battery Monitoring System
Battery Type
1.2V, 192blocks, 1string, 1set UPS
Used For
Lead Acid,  Nickel Battery
Monitoring Parameter
Battery Voltage/Battery String Current/Voltage/Ambient Temperature

Power Requirements
TV module:powered from the battery,less than 12mA(2V) or 4mA(12V)
TC module:DC8~13V,2W
CM module:85~264VAC,100V~370VDC,15W
Communications Interfaces
TV module:serial port, meet MODBUS protocol, support 130 devices on each bus
TC module:serial port, meet MODBUS protocol
CM module:RS485, Ethernet Port , meet MODBUS/RTU,MODBUS/TCP and SNMP protocol
Environmental
Storage temperature: -10℃~70℃,5%~90%RH
Operating temperature:-5℃~50℃,5%~90%RH
Application
Datacenter/Communications/Transportation, etc.


BMS Components

Overview

• Continuous 24/7 on-line monitoring
• One TV module monitors one cell, including voltage and temperature 
• Software is available to collect data from TV module
• Serial port with Optical isolation, meet MODBUS protocol, easy to be accessed by UPS controller
• Easy to install without specialized training



UL VW-1 Test Method


All cables including voltage collecting cable, internal testing cable and other conneting cables are all flame retardant lines, and are in compliance with the fire retardant requirements specified in the UL VW-1 and GBT 18380.1 standard.






Packaging & Delivery


Standard Export Carton

Normal Size: 52.3*33.8*19.5



Main Products

Wireless BMS

H3G-TA BMS

H3G-TV BMS

IR Module Sensor

Voltage Module Sensor

Control Module

Related Product

CLICK HERE!

    CLICK HERE!

   CLICK HERE!

Application & Cases

• IT Enterprise &Data centers
• Telecommunications
• Battery supplied applications
• Utilities 
• Fire &Safety system

• UPS Systems

• Transportations

• Storage Energy

Remote monitoring
• Base Stations

Project Cases


User Name Battery Situation Installation Site

About US

At HUASU battery monitoring and management is all we do. We keep on researching it intimately, so you don't have to. Our company was established on year 2005, 4 generations (1.2V, 2V, 6V &12V concentrated system, cellcheck system, wireless system) BMS have been developed. 


We provide BMS products and related services to the world, such as Vertiv (Emerson), Schneider, Eaton, etc.


Profession, specialty, refinement and particularity have been the keys to HUASU's success.

Contact us

Factory Add: 2nd& 3rd Floor of No. 3 Building, No. 1418-50 Moganshan Road, Hangzhou, China

Tel:+86-571-86693075

Fax:+86-571-87968969
Skype: huasu.joanna

Mob/WeChat/WhatsApp:+86-18324428238
Website://huasu-tech.com

LinkedIn: https://www.linkedin.com/in/joanna-chan-a22b9983

Facebook: https://www.facebook.com/huasu.joanna
Twitter: https://twitter.com/BMS_HuasuJoanna

Email: joanna@huasucn.com

Our Team

Produce Line
FAQ

Q1. Why monitoring battery internal Resistance?

A:  Generally, we confirm the battery situation through discharging of the battery. With this handling, we can work on the real capacity but it is very time-consuming. After doing some research, we find the internal resistance of the battery will be increased that due to various causes of capacity decline. If we regularly monitor the internal resistance of the battery and compare it with the initial internal resistance, it will be easy to detect the performance change of the battery and also find out the problem battery. 


Q2. Why monitoring battery temperature?

A: Battery temperature is like human body temperature, when there is a problem with the battery internal temperature will tend to rise, generally like the battery internal part of short circuit, charging voltage is too high will cause temperature rise.
Therefore, the problem of battery pack can be detected as early as possible by monitoring the temperature inside the cell.


Q3. Can your products be discharged remotely?

A: Yes, the control unit can be controlled remotely, and the capacity unit can be controlled by the control unit to discharge the
battery. But when discharging, the battery pack needs to be operated manually or other control methods to separate from the power
supply system. We have done the whole system including the charger by technology project of remote control, but this method is not promotion, mainly is the present charger stability DC screen is not enough, manufacturers can not guarantee the safety and
effectiveness of the remote control function, easily lead to loss of control. At present, the technology of remote discharge
products in the market is not mature, as a pilot can, it is not suitable to promote, it is recommended that users do not use this
product at present.


Q4. How does the product solve the line interference and the environmental interference?

A: We have considered various interference conditions during the design , and special EMC is processing on the circuit which can
meet the requirements specified in UL and DL / T856 - 2004 , and we have corresponding EMC test reports.


Q5. The equipment can access to the third party system? How to access?

A: Yes. It is very easily access to your third party system. Generally, you only take one or two days to put programs. H3G system
comes with a special serial port for the use of third party system, support the MODBUS protocol. The specific access method and
communication protocol can be provided by our customer service department.