Display Panel Remote Controller 39817655 Plc Controller for Screw Air Compressor

Share on:


Price:RUB 23,014.91
Price in USD:Details

Quantity:


Product Overview

Description

Display Panel Remote Controller 39817655 Plc Controller for Screw Air Compressor

1. INSTALLATION: we will offer the Installation mamual if you order it.

2. Controller Function and Technical Parameter:

2.1 Ambient temperature: -20degree to +60degree; Humidity: <=98%

2.2 Digital input&output: 6 point of digital input( function optional), 6 points of digital relay output.

2.3 Analog input&output: 1 point of PT100 temperature input, 1 ponit of 4-20mA pressure input, 2 groups of three phases current input(CT PROVIDED)

2.4 Input voltage of phases, 380V/220V. 

2.5 High voltage, low voltage protection. 

2.6 Controller operation power supply: AC16-28V.15VA


3. Power Specification sheet for corresponding motor


Contact informtation

Sincerely
HongKong Jiubei Industry Limited
Dongguan City Jiubei Compressor Part Co.,Ltd.
Miss Carrie
E-mail/Skype:sales7@cnjiubei.com
Email: zakf3@screwaircompressor.cn
QQ:2568123966
whatsapp/wechat:+8613580987261
Tel:+8613580987261


Specification
Current Range(A)
Corresponding main motor power(KW)
Remark
Description
MAM6080(20)
8~20
BELOW 11
FAN HAS THREE LEVELS OF CURRENT, SUCH AS 0.2-2.5A, 1-5A AND 4-10A, DETERMINED-BY CURRENT OF MOTOR
MAM6080(40)
16~40
11-18.5
MAM6080(100)
100
22-45
MAM6080(200)
200
55-90
MAM6080(400)
400
110
MAM6080(600/5)
600/5
200-250
WITH CT


Trouble shooting

Failure
Reason
Solution
High discharge temperature
Bad vent condition, Oil shortage ect.
Check the vent condition and lubricant amount ect
Temperature Sensor Failure
cable broken or sensorfailure
check the wirin and sensor
High Pressure
Pressure  too high or the pressure sensor failure
Check the pressure and pressure sensor
Pressure Sensor Failure
cable broken, sensor failure or the cables connect reversely
check the wiring and pressure transmitter
Open Phase
power open phase or the contactor failure
check the power and ocntactors
Overload
voltage too low, tubes block, bearing wear off or other mechanical failure or wrong set date ect
check the set date, voltage, bearing, tubes and other mechanical system
Unbalance
Current unbalance, contactor failure or the internal open loop of the motor
check the power, contactor and the motor
Wrong Phase Sequence
phase sequence reversal or open phase
check the wiring 
Motor Overload During Start
Master start time set to less than the star delta delay time
reset the master start time longer than star delay+2seconds
Main Contactor Shakes Frequently
the emergency stoop button is loose or controller is reset by interference.
check if the coil of contactor connects with RC snubber or not
Inverter Communication Fault
wrong set of relatively parameter of controller and inverter, communication cable loose
check the set date, check the cable

We also deal other replacement parts

          Coupling

          Solenoid valve

          Regulator

          Service Kits

          Drain valve

          Sensor

          Controller

          ......

Hot Sale Products
Other Parts We Sale

Cooler Parts 

A-1613836400 

A-1622376800

A-1623712100

A-V1621848700

A-1614959000

A-1614958900

A-1614958800

Sensor Parts

A-1089057578

A-1089962512                                                

A-1089057573

A-1089057471

L-2200702805

A-1089957903

A-1089051505

 Controller Parts

A-1900071071

A-1900002009

A-1900520032

A-1900070101/2/3/4/5/6

A-1900070125/24

A-1900071032/31/12/11

MAM-860

Intake valve Parts

A-1622515680

A-1622171380

I- 54747899

S-02250073-227

S-02250130-050

A-1622351300

A-1613900800

A-1613679300

A-1613814400

A-1622316200

A-1613815000

Soleoid valve Parts

A-1089042821                                         

A-2200599753

A-1089062157

A-1089062140

A-1089062101

I-39137492

I-22282529

I-54579248

K-A11030074

K-A11383974

A-1089943924                                             

Coupling Parts

A-2903101601

A-1614983600

S-88290003-403

S-02250152-674

10R/20R/30R/40R/50R/60R/70R/80R

GS Seires coupling

A-1613948800

A-1614873900

E series coupling 

A-1615418500

K-A100009329

Our Service

BETTER SERVICE

1)Pre-sale services:
24 hours' online service for the prompt reply.

2)Sale services:
Our professional engineer team will provide you the satisfied scheme according to your demand.

3)After-sale services:
To offer the better service, we will do the satisfaction survey for each sale experance and regularly pay return visit to customers.

Packing & Delivery
Packaging
Size
65 (L) *45 (W) * 65 (H)
Weight
25KG



Packaging Details
The normal package is carton box(Size: L*W*H).
if the goods is the fan motor, airend and cooler, we will use the export wooden box. the size will be customized. 
Delivery
Express
DHL, TNT, UPS, FEDEX, SF, EMS, SPECIAL LINE ...
Shipping via Sea
Shipping via sea suittable for big QTY products, and the products dimension will be more than the weight. 
Related Products

1622075800 1613815000

91.8% Response Rate

1622171300 1622349080

91.8% Response Rate

1622364800 1622377800

91.8% Response Rate

contact information

0.0133 s.